Record Date: 07/14/2023 00:00 | |||
Identifier: | F-DET-POL-EPOL.1 | WBS: | 6.10.14.01 |
Date Modified: | 07/14/2023 00:00 | TBD: | FALSE |
Status Date: | 07/14/2023 00:00 | Status: | APPROVED |
Description: | Laser shall provide a "photon target" for Compton reaction. | ||
Comments: |
No archive versions
Parents | |
G-DET-POL-EPOL.1 | The EIC electron polarimeter system shall provide a measurement of the absolute beam polarization in the ESR and RCS. The ESR Compton must measure the polarization bunch-by-bunch and be sensitive to the beam transverse polarization profile. |
Children | |
P-DET-POL-EPOL.1 | The laser average power shall be 5-10 W, with a wavelength = 532 nm. |
P-DET-POL-EPOL.2 | The laser beam M2 will be approximately 1 (diffraction limited). |