Record Date: 05/16/2025 17:04 | |||
Identifier: | P-DET-POL-EPOL-ESR.10 | WBS: | 6.10.14.01.01 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | Approved | |
Description: | The photon detector strip detector pitch shall be ~100 um (to be verified). | ||
Comments: |
Record Date: 05/15/2025 20:34 | |||
Identifier: | P-DET-POL-EPOL-ESR.10 | WBS: | |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | ||
Description: | The photon detector strip detector pitch shall be ~100 um (to be verified). | ||
Comments: |
Record Date: 01/27/2025 16:43 | |||
Identifier: | P-DET-POL-EPOL-ESR.10 | WBS: | 6.10.14.01.01 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | Approved | |
Description: | The photon detector strip detector pitch shall be ~100 um (to be verified). | ||
Comments: |
Parents | |
F-DET-POL-EPOL-ESR.4 | A calorimeter will be used to measure backscattered photon energy. |
F-DET-POL-EPOL-ESR.5 | The photon detector system will be at least 20 to 25 meters from the Compton IP (to be verified). |
Children | |
No children. |