Requirement Details
Electron Ion Collider

P-DET-POL-EPOL-ESR.8
Requirement details, history, relationships and interfaces associated with requirement P-DET-POL-EPOL-ESR.8
CURRENT RECORD
ARCHIVE RECORDS
RELATIONSHIPS
INTERFACES
| Record Date: 03/02/2026 15:19 | |||
| Identifier: | P-DET-POL-EPOL-ESR.8 | WBS: | 6.03.01.11.01.01 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Approved | |
| Description: | The electron strip detector pitch shall be 400 um or smaller (to be verified). | ||
| Comments: | |||
| Record Date: 05/16/2025 17:04 | |||
| Identifier: | P-DET-POL-EPOL-ESR.8 | WBS: | 6.10.14.01.01 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Approved | |
| Description: | The electron strip detector pitch shall be 400 um or smaller (to be verified). | ||
| Comments: | |||
| Record Date: 05/15/2025 20:34 | |||
| Identifier: | P-DET-POL-EPOL-ESR.8 | WBS: | |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | ||
| Description: | The electron strip detector pitch shall be 400 um or smaller (to be verified). | ||
| Comments: | |||
| Record Date: 01/27/2025 16:43 | |||
| Identifier: | P-DET-POL-EPOL-ESR.8 | WBS: | 6.10.14.01.01 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Approved | |
| Description: | The electron strip detector pitch shall be 400 um or smaller (to be verified). | ||
| Comments: | |||
| Parents | |
| F-DET-POL-EPOL-ESR.1 | A strip detector will be used to detect scattered electrons from (at least) asymmetry zero crossing to kinematic endpoint. |
| F-DET-POL-EPOL-ESR.3 | The strip detector shall be used to detect back-scattered photons with sufficient resolution measure the spatial asymmetry. |
| Children | |
| No children. | |