Identifier: | P-DET-PID-BAR-DIRC.2 | WBS: | 6.10.04 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | Approved | |
Description: | The PID Detector in the barrel region will require appropriate support DC voltage and power for operating detector sensors and associated electronics. HV up to 2000V negative is for 5x72 channels and LV for 4x72 channels. | ||
Comments: |
Record Date: 05/15/2025 20:34 | |||
Identifier: | P-DET-PID-BAR-DIRC.2 | WBS: | |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | ||
Description: | The PID Detector in the barrel region will require appropriate support DC voltage and power for operating detector sensors and associated electronics. HV up to 2000V negative is for 5x72 channels and LV for 4x72 channels. | ||
Comments: |
Record Date: 01/27/2025 16:43 | |||
Identifier: | P-DET-PID-BAR-DIRC.2 | WBS: | 6.10.04 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | Approved | |
Description: | The PID Detector in the barrel region will require appropriate support DC voltage and power for operating detector sensors and associated electronics. HV up to 2000V negative is for 5x72 channels and LV for 4x72 channels. | ||
Comments: |
Parents | |
F-DET-PID.1 | The PID detector system will require adequate infrastructure resources (i.e. power, cooling, cryogens, etc.) to ensure it can function reliably during continous operations. |
F-DET-PID.3 | The PID detector system and its support systems must fit in the available space AND provide adequate plenums and pathways for the delivery of services, resources and communications, and for the removal of heat and waste during operations. |
Children | |
No children. |