Record Date: 10/10/2024 00:00 | |||
Identifier: | G-DET-MAG.1 | WBS: | 6.10.07 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | APPROVED | |
Description: | The EIC detector magnet shall provide a central field, a sufficiently large room temperature bore, and a magnet length consistent with the detector need to fulfill EIC science requirements | ||
Comments: |
No archive versions
Parents | |
No parents. | |
Children | |
F-DET-MAG-I&C.1 | The magnet control and instrumentation shall be able to read all the temperature and stress sensor in the magnet. |
F-DET-MAG-CCR.1 | The magnet shall require a cryocan and cryogenic line that will deliver Liquid Helium to the solenoid. |
F-DET-MAG-PSU.1 | Magnet power shall be able to supply required current to the magnet to produce a 1.7 T central field, with a stretch goal of 2 T. |
F-DET-MAG.1 | The EIC detector magnet shall fulfill the field specification (as specified in the magnetic field specification document), the main area for field specifications are (i) flat field area, (ii) RICH detector area, (iii) stray field at IR magnets, and (iv) stray field at the RCS location. |