G-DET-MAG.1
Requirement details, history, relationships and interfaces associated with requirement G-DET-MAG.1
CURRENT RECORD
ARCHIVE RECORDS
RELATIONSHIPS
INTERFACES
Record Date: 07/14/2023 00:00 | |||
Identifier: | G-DET-MAG.1 | WBS: | 6.10.07 |
Date Modified: | 07/14/2023 00:00 | TBD: | FALSE |
Status Date: | 07/14/2023 00:00 | Status: | APPROVED |
Description: | The EIC detector magnet shall provide a central field, a sufficiently large room temperature bore, and a magnet length consistent with the detector need to fulfill EIC science requirements | ||
Comments: |
No archive versions
Parents | |
No parents. | |
Children | |
F-DET-MAG-CCR.1 | The cryocan should be able to hold the required volume of Liquid Helium and shall be protected for pressure overages. |
F-DET-MAG-CCR.2 | The cryo-flex line should have sufficiently low losses, so that the input temperature to the magnet can be maintained. |
F-DET-MAG-I&C.1 | The magnet control and instrumentation shall be able to read all the temperature and stress sensor in the magnet. |
F-DET-MAG-PSU.1 | Magnet power shall be able to supply required current to the magnet to produce a 1.7 T central field, with a stretch goal of 2 T. |
F-DET-MAG.2 | The EIC detector magnet shall fulfill the field specification (as specified in the magnetic field specification document), the main area for field specifications are (i) flat field area, (ii) RICH detector area, (iii) stray field at IR magnets, and (iv) stray field at the RCS location. |