Record Date: 10/10/2024 00:00 | |||
Identifier: | F-DET-MAG.1 | WBS: | 6.10.07 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | APPROVED | |
Description: | The EIC detector magnet shall fulfill the field specification (as specified in the magnetic field specification document), the main area for field specifications are (i) flat field area, (ii) RICH detector area, (iii) stray field at IR magnets, and (iv) stray field at the RCS location. | ||
Comments: |
No archive versions
Parents | |
G-DET-MAG.1 | The EIC detector magnet shall provide a central field, a sufficiently large room temperature bore, and a magnet length consistent with the detector need to fulfill EIC science requirements |
Children | |
P-DET-MAG.9 | The EIC detector magnet shall be able to operate at 4.5K (liquid Helium). |
P-DET-MAG.10 | The detector solenoid shall be able to operate at a lower field (0.5 T), without sacrificing the field quality. |
P-DET-MAG.11 | The detector solenoid shall be aligned along the electron axis. |
P-DET-MAG.13 | The detector solenoid must produce a consistent, stable magnetic field that is sufficient to satisfy the requirements of all subordinate detectors. |
P-DET-MAG.14 | The detector solenoid's magnetic field extends beyond its physical boundaries, and must be accounted for and managed. |
P-DET-MAG.15 | The flux return shall reduce the magnetic field to no more than 10 Gauss at the location of the most nearby active beam transport elements (IR magnets and RCS beamline). |
This function not yet implemented.