F-DET-MAG-CCR.1
Requirement details, history, relationships and interfaces associated with requirement F-DET-MAG-CCR.1
CURRENT RECORD
ARCHIVE RECORDS
RELATIONSHIPS
INTERFACES
Record Date: 05/16/2025 17:04 | |||
Identifier: | F-DET-MAG-CCR.1 | WBS: | 6.10.07.01 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | Approved | |
Description: | The magnet shall require a cryocan and cryogenic line that will deliver Liquid Helium to the solenoid. | ||
Comments: |
Record Date: 05/15/2025 20:34 | |||
Identifier: | F-DET-MAG-CCR.1 | WBS: | |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | ||
Description: | The magnet shall require a cryocan and cryogenic line that will deliver Liquid Helium to the solenoid. | ||
Comments: |
Record Date: 01/27/2025 16:43 | |||
Identifier: | F-DET-MAG-CCR.1 | WBS: | 6.10.07.01 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | Approved | |
Description: | The magnet shall require a cryocan and cryogenic line that will deliver Liquid Helium to the solenoid. | ||
Comments: |
Parents | |
G-DET-MAG.1 | The EIC detector magnet shall provide a central field, a sufficiently large room temperature bore, and a magnet length consistent with the detector need to fulfill EIC science requirements |
Children | |
P-DET-MAG-CCR.2 | The cryo-flex line should be long enough so that the magnet can be rolled out of the Wide-Angle Hall into the Assembly Hall without disconnecting the cryo connection. |
P-DET-MAG-CCR.1 | The cryocan should be able to hold the required volume of Liquid Helium and shall be protected for pressure overages. |
P-DET-MAG-CCR.3 | The cryo-flex line should have sufficiently low losses, so that the input temperature to the magnet can be maintained. |