Requirement Details
Electron Ion Collider
F-DET-INF.7
Requirement details, history, relationships and interfaces associated with requirement F-DET-INF.7
CURRENT RECORD
ARCHIVE RECORDS
RELATIONSHIPS
INTERFACES
Record Date: 05/16/2025 17:04 | |||
Identifier: | F-DET-INF.7 | WBS: | 6.10.10 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | Approved | |
Description: | Predefined detector envelopes shall not be infringed upon. | ||
Comments: |
Record Date: 05/15/2025 20:34 | |||
Identifier: | F-DET-INF.7 | WBS: | |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | ||
Description: | Predefined detector envelopes shall not be infringed upon. | ||
Comments: |
Record Date: 01/27/2025 16:43 | |||
Identifier: | F-DET-INF.7 | WBS: | 6.10.10 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | Approved | |
Description: | Predefined detector envelopes shall not be infringed upon. | ||
Comments: |
Parents | |
G-DET-INF.9 | The infrastructure systems will be functionally integrated with the other detectors, with the interaction region components, and with the facility infrastructure. |
G-DET-INF.10 | The infrastructure systems must fit within the available space in the experimental hall, and be consistent with the available infrastructure and resources. |
Children | |
P-DET-INF-STD-SVCGAP.1 | Area needed around pfRICH: 2000 cm2 + 10% = 2200 cm2 |
P-DET-INF-STD-SVCGAP.2 | Area needed around EEEMcal: 2150cm2 + 10% = 2365 cm2 |
P-DET-INF-STD-SVCGAP.4 | Area needed between dRICH boxes: 4800 cm2 + 10% = 5280 cm2 |
P-DET-INF-STD-SVCGAP.3 | Area needed between CF tube and dRICH: 4350 cm2 + 10% = 4785 cm2 |
P-DET-INF-STD-SVCGAP.5 | Area needed between dRICH and HCAL: 5650 cm2 + 10% = 6215 cm2 |
This function not yet implemented.