Record Date: 10/10/2024 00:00 | |||
Identifier: | F-DET-INF.1 | WBS: | 6.10.10 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | APPROVED | |
Description: | All components, whether procured or manufactured, will, at a minimum, meet the standards specified by the EIC project AND meet the additional standards and specifications identified in these requirements. | ||
Comments: |
No archive versions
Parents | |
G-DET-INF.2 | All components, equipment and assemblies will comply with standards established by the EIC project. |
Children | |
P-DET-INF-STD-ALIGN.1 | The main barrel and both endcaps shall be rotated 8mrad counterclockwise about the Y axis (looking top down). |
P-DET-INF-STD-ALIGN.2 | The tolerance for this measurement shall be ± 1mrad. |
P-DET-INF-STD-SAF.1 | Safety factors will be calculated based off yield strength. |
P-DET-INF-STD-SAF.2 | Parts with a safety factor of 3 or greater will be generally accepted and will not require further review. |
P-DET-INF-STD-SAF.3 | Parts with a safety factor of 1.5 to 3 are required to be internally reviewed to determine if it’s acceptable. |
P-DET-INF-STD-SAF.4 | Parts with a safety factor of 1.5 or less will be considered unacceptable. |
P-DET-INF-STD-SAF.5 | Bolts with a safety factor of 2 or greater will be generally accepted and will not require further review. |
P-DET-INF-STD-SAF.6 | Bolts with a safety factor of 1 to 2 are required to be internally reviewed to determine if it’s acceptable. |
P-DET-INF-STD-SAF.7 | Bolts with a safety factor of 1 or less will be considered unacceptable. |
P-DET-INF-STD-SAF.8 | Engineering judgment will be used for identifying and disregarding any singularities which may go below these minimums. |