Requirement Details
Electron Ion Collider

F-DET-INF-CRYO.1
Requirement details, history, relationships and interfaces associated with requirement F-DET-INF-CRYO.1
CURRENT RECORD
ARCHIVE RECORDS
RELATIONSHIPS
INTERFACES
| Record Date: 03/02/2026 15:19 | |||
| Identifier: | F-DET-INF-CRYO.1 | WBS: | 6.03.01.09 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Approved | |
| Description: | A cryogenic transfer system shall be provided within the experimental hall and assembly hall at IP6 to allow cryogenic distribution for the experimental solenoid. | ||
| Comments: | |||
| Record Date: 10/23/2025 17:13 | |||
| Identifier: | F-DET-INF-CRYO.1 | WBS: | 6.10.10 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Approved | |
| Description: | A cryogenic transfer system shall be provided within the experimental hall and assembly hall at IP6 to allow cryogenic distribution for the experimental solenoid. | ||
| Comments: | |||
| Record Date: 05/16/2025 17:04 | |||
| Identifier: | F-DET-INF-CRYO.1 | WBS: | 6.10.10 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Approved | |
| Description: | A cryogenic transfer system shall be provided within the collider hall to allow cryogenic distribution for the experimental solenoid. | ||
| Comments: | |||
| Record Date: 05/15/2025 20:34 | |||
| Identifier: | F-DET-INF-CRYO.1 | WBS: | |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | ||
| Description: | A cryogenic transfer system shall be provided within the collider hall to allow cryogenic distribution for the experimental solenoid. | ||
| Comments: | |||
| Record Date: 01/27/2025 16:43 | |||
| Identifier: | F-DET-INF-CRYO.1 | WBS: | 6.10.10 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Approved | |
| Description: | A cryogenic transfer system shall be provided within the collider hall to allow cryogenic distribution for the experimental solenoid. | ||
| Comments: | |||
| Parents | |
| G-DET-INF.4 | Infrastructure systems for the collider hall shall include all power, water, environmental cooling, cryogenics, gas handling, clean compressed air delivery, space, fire protection, Helium Leak Detection, ODH Detection and any other Personnel Safety Systems, Cryo Protection, material handling and support systems required to operate the entire detector systems. |
| Children | |
| P-DET-INF-CRYO.1 | The cryogenic transfer system must be installed in the available space and have no interferences with new and existing infrastructure. |
| P-DET-INF-CRYO.3 | To limit the coil temperature below 100k, the magnet transport shall be completed within 2 days of discconection of cryogenic services to the phase separator |
| P-DET-INF-CRYO.2 | The cryogenic transfer system will have a support structure and connectors that allow the central detector to be relocated between the experimental hall and the assembly area without disconnection. |
| P-DET-INF-CRYO.4 | During detector alignment, the DBX transfer line shall be flexible against magnet motion of 2" in the Y and ±1" in the X and Z direction, relative to the electronic racks. |