Record Date: 10/10/2024 00:00 | |||
Identifier: | F-DET-HCAL.6 | WBS: | 6.10.06 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | APPROVED | |
Description: | The Hadronic Calorimetry subsystem and its support systems must fit in the available space AND provide adequate plenums and pathways for the delivery of services, resources and communications, and for the removal of heat and waste during operations. | ||
Comments: |
No archive versions
Parents | |
G-DET-HCAL.3 | The Hadronic Calorimetry subsystem will be functionally integrated with the other detectors, with the interaction region components, and with the facility infrastructure. |
G-DET-HCAL.4 | The Hadronic Calorimetry subsystem must fit within the available space in the experimental hall, and be consistent with the available infrastructure and resources. |
Children | |
P-DET-HCAL.1 | Must be compact enough to fit in the limited space allocated for the EIC detector, but at the same time provide a hermetic coverage and have sufficient depth in order to efficiently contain the hadronic showers. |
P-DET-HCAL.2 | The HCal systems will require a structural support system to carry the cumulative weight of the detectors and peripheral services, and to distribute that load to other supporting infrastructure or to the floor, and will require survey marks to determine their physical location. |
P-DET-HCAL.3 | The HCal systems will require cooling infrastructure that is sufficient to ensure the operating temperature remains within an acceptable range. |
P-DET-HCAL.4 | The HCal systems will require electrical power to support the operation of the detector sub-components and electronics. |
P-DET-HCAL.5 | The HCal systems will require communications infrastructure to support data collection, monitoring and control. |
P-DET-HCAL.7 | HCal layout shall minimize the gaps in coverage between barrel and endcaps. |