Record Date: 10/11/2023 00:00 | |||
Identifier: | P-DET-HCAL-FWD.5 | WBS: | 6.10.06 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | APPROVED | |
Description: | Granularity (longitudinal tower size) should be adequate to allow for association of showers starting at different depth to the corresponding charged and neutral hadrons. At least 5 longitudinal segments should be read out to determine the shower maximum reliably. For higher rapidity the segmentation should be increased due to the higher particle density | ||
Comments: |
No archive versions
Parents | |
F-DET-HCAL-FWD.2 | The design must be coupled well with a compensated forward e/m calorimeter for high precision jet energy measurements. |
Children | |
No children. |