Requirement Details
Electron Ion Collider

P-DET-HCAL-FWD.4
Requirement details, history, relationships and interfaces associated with requirement P-DET-HCAL-FWD.4
CURRENT RECORD
ARCHIVE RECORDS
RELATIONSHIPS
INTERFACES
| Record Date: 05/16/2025 17:04 | |||
| Identifier: | P-DET-HCAL-FWD.4 | WBS: | 6.10.06 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Approved | |
| Description: | Must have tower depth of 6-7 interaction lengths (together with the e/m section) in order to avoid longitudinal leakage for highest energy hadrons at the EIC. | ||
| Comments: | |||
| Record Date: 05/15/2025 20:34 | |||
| Identifier: | P-DET-HCAL-FWD.4 | WBS: | |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | ||
| Description: | Must have tower depth of 6-7 interaction lengths (together with the e/m section) in order to avoid longitudinal leakage for highest energy hadrons at the EIC. | ||
| Comments: | |||
| Record Date: 01/27/2025 16:43 | |||
| Identifier: | P-DET-HCAL-FWD.4 | WBS: | 6.10.06 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Approved | |
| Description: | Must have tower depth of 6-7 interaction lengths (together with the e/m section) in order to avoid longitudinal leakage for highest energy hadrons at the EIC. | ||
| Comments: | |||
| Parents | |
| F-DET-HCAL-FWD.2 | The design must be coupled well with a compensated forward e/m calorimeter for high precision jet energy measurements. |
| Children | |
| No children. | |
This function not yet implemented.