Requirement Details
Electron Ion Collider

F-DET-HCAL-BCK.2
Requirement details, history, relationships and interfaces associated with requirement F-DET-HCAL-BCK.2
CURRENT RECORD
ARCHIVE RECORDS
RELATIONSHIPS
INTERFACES
| Record Date: 03/02/2026 15:19 | |||
| Identifier: | F-DET-HCAL-BCK.2 | WBS: | 6.03.01.05 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Approved | |
| Description: | Shall accommodate the ability to complement e/m calorimeter by tail catching capability for electron ID purposes, especially below 3-4 GeV/c. | ||
| Comments: | |||
| Record Date: 05/16/2025 17:04 | |||
| Identifier: | F-DET-HCAL-BCK.2 | WBS: | 6.10.06 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Approved | |
| Description: | Shall accommodate the ability to complement e/m calorimeter by tail catching capability for electron ID purposes, especially below 3-4 GeV/c. | ||
| Comments: | |||
| Record Date: 05/15/2025 20:34 | |||
| Identifier: | F-DET-HCAL-BCK.2 | WBS: | |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | ||
| Description: | Shall accommodate the ability to complement e/m calorimeter by tail catching capability for electron ID purposes, especially below 3-4 GeV/c. | ||
| Comments: | |||
| Record Date: 01/27/2025 16:43 | |||
| Identifier: | F-DET-HCAL-BCK.2 | WBS: | 6.10.06 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Approved | |
| Description: | Shall accommodate the ability to complement e/m calorimeter by tail catching capability for electron ID purposes, especially below 3-4 GeV/c. | ||
| Comments: | |||
| Parents | |
| G-DET-HCAL-BCK.1 | Backward HCal shall provide functionality of a tail catcher for the high resolution e/m calorimeter in electron identification, as well as for jet kinematics measurement at small Bjorken x |
| Children | |
| P-DET-HCAL-BCK.2 | Shall provide capability to have energy resolution s(E)/E ~ 100%/sqrt(E) + a 10% constant term. |
| P-DET-HCAL-BCK.4 | Must provide space to have tower depth of 3-4 interaction lengths (together with the e/m PWO crystal calorimeter) in order to suppress longitudinal leakage for relatively small hadron energies in the e-endcap. |
This function not yet implemented.