Identifier: | P-DET-ELEC.11 | WBS: | 6.10.08 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | Approved | |
Description: | The detector ground (i.e., Clean Ground) shall be segregated from other equipment grounding. The grounding around the solenoid and the south platform from the detector ground reference, which shall be isolated from other systems and structures and connected to the experimental area ground via six (6) low impedance, insulated 4/0 wires. Other equipment, such as the solenoid power supplies and control systems, shall connect to the experimental area grounding connection separately from the clean ground. All connections shall be effected via low impedance insulated wires (e.g., 4/0). These wires shall have differently colored insulation for easy identification of segregated grounds. | ||
Comments: |
No archive versions
Parents | |
F-DET-ELEC.5 | All components, whether procured or manufactured, will, at a minimum, meet the standards specified by the EIC project AND meet the additional standards and specifications identified in these requirements. |
F-DET-ELEC.6 | Where not governed by specific standards, components will be implemented, installed, and utilized in a manner that is consistent with industry best practices. |
Children | |
No children. |