Requirement Details
Electron Ion Collider
P-DET-ELEC.5
Requirement details, history, relationships and interfaces associated with requirement P-DET-ELEC.5
- CURRENT RECORD
- ARCHIVE RECORDS
- RELATIONSHIPS
- INTERFACES
Record Date: 10/11/2023 00:00 | |||
Identifier: | P-DET-ELEC.5 | WBS: | 6.10.08 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | APPROVED | |
Description: | The detector ground (i.e., Clean Ground) shall be segregated from other equipment grounding. The grounding around the solenoid and the south platform from the detector ground reference, which shall be isolated from other systems and structures and connected to the experimental area ground via six (6) low impedance, insulated 4/0 wires. Other equipment, such as the solenoid power supplies and control systems, shall connect to the experimental area grounding connection separately from the clean ground. All connections shall be effected via low impedance insulated wires (e.g., 4/0). These wires shall have differently colored insulation for easy identification of segregated grounds. | ||
Comments: |
No archive versions
Parents | |
No parents. | |
Children | |
No children. |
This function not yet implemented.