Record Date: 10/11/2023 00:00 | |||
Identifier: | F-DET-ECAL.9 | WBS: | 6.10.05 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | APPROVED | |
Description: | Shall provide photon measurements down to 100 MeV. | ||
Comments: |
No archive versions
Parents | |
G-DET-ECAL.1 | EMCal shall provide measurements of photons, including ones from pi0, eta and other decays; and shall play a key role to identify scattered and decay electrons and measure their kinematic parameters |
Children | |
P-DET-ECAL-BCK.6 | System shall have low material budget on the way from the vertex: <5%X0 in the 1st half a way, or <10%X0 on the second half a way, or <30%X0 just in front of EMCal (within 10cm). |
P-DET-ECAL.3 | The monitoring system shall contain: Light system (LED or laser), test pulse (for electronics), dark current (for SiPM). |