G-DET-ECAL-BCK.1
Requirement details, history, relationships and interfaces associated with requirement G-DET-ECAL-BCK.1
- CURRENT RECORD
- ARCHIVE RECORDS
- RELATIONSHIPS
- INTERFACES
Record Date: 10/10/2024 00:00 | |||
Identifier: | G-DET-ECAL-BCK.1 | WBS: | 6.10.05 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | APPROVED | |
Description: | Backward EMCal shall identify scattered electrons and measure their energy, in low and medium Q2 events; it also serves to identify decay electrons, e.g. from vector or heavy flavor meson decays, and measure DVCS photons and decay photons | ||
Comments: |
No archive versions
Parents | |
No parents. | |
Children | |
F-DET-ECAL-BCK.1 | Shall provide high precision measurements for electrons up to 18 GeV and pseudo rapidity down to -3.5. |
F-DET-ECAL-BCK.2 | Shall provide measurements of scattered electrons for the events down to Q2=1 GeV2 (=> acceptance requirements). |
F-DET-ECAL-BCK.3 | Must provide strong eID capabilities down to 1 GeV/c. |
F-DET-ECAL-BCK.4 | Shall provide photon measurements up to 18 GeV. |
F-DET-ECAL-BCK.5 | Must provide discrimination between single photon and merged photon from pi0 decay up to 18 GeV. |
F-DET-ECAL-BCK.7 | A cooling system shall be provided for the lead-tungstate based detector. |