Requirement Details
Electron Ion Collider
F-DET-ECAL-BCK.6
Requirement details, history, relationships and interfaces associated with requirement F-DET-ECAL-BCK.6
CURRENT RECORD
ARCHIVE RECORDS
RELATIONSHIPS
INTERFACES
Record Date: 07/14/2023 00:00 | |||
Identifier: | F-DET-ECAL-BCK.6 | WBS: | 6.10.05 |
Date Modified: | 07/14/2023 00:00 | TBD: | FALSE |
Status Date: | 07/14/2023 00:00 | Status: | APPROVED |
Description: | Must provide photon measurements down to 50 MeV (to measure radiated photons). | ||
Comments: |
No archive versions
Parents | |
G-DET-ECAL-BCK.1 | Backward EMCal shall identify scattered electrons and measure their energy, in low and medium Q2 events; it also serves to identify decay electrons, e.g. from vector or heavy flavor meson decays, and measure DVCS photons and decay photons |
Children | |
P-DET-ECAL-BCK.6 | System shall have low material budget on the way from the vertex: <5%X0 in the 1st half a way, or <10%X0 on the second half a way, or <30%X0 just in front of EMCal (within 10cm). |