Requirement Details
Electron Ion Collider
F-DET-ANC.3
Requirement details, history, relationships and interfaces associated with requirement F-DET-ANC.3
CURRENT RECORD
ARCHIVE RECORDS
RELATIONSHIPS
INTERFACES
Record Date: 07/14/2023 00:00 | |||
Identifier: | F-DET-ANC.3 | WBS: | 6.10.11 |
Date Modified: | 07/14/2023 00:00 | TBD: | FALSE |
Status Date: | 07/14/2023 00:00 | Status: | APPROVED |
Description: | The off-momentum detectors shall provide a means to measure charged particles (e.g. primarily protons and/or other decay particles), where this particles have a different magnetic rigidity than the beam being used. | ||
Comments: |
No archive versions
Parents | |
G-DET-ANC.2 | The forward ancillary detectors shall provide a means to measure forward going charged particles (including those close to the beam core), forward going neutral particles, and to tag charged and neutral particles following decay. |
Children | |
No parents. |