| Record Date: 03/02/2026 15:19 | |||
| Identifier: | P-DET-ANC-ZDC.2 | WBS: | 6.03.01.10 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Approved | |
| Description: | ZDC system active area will have dimensions 60 [cm] in X and 60 [cm] in Y and <200 [cm] in Z | ||
| Comments: | |||
| Record Date: 08/05/2025 20:59 | |||
| Identifier: | P-DET-ANC-ZDC.2 | WBS: | 6.10.11 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Approved | |
| Description: | ZDC system active area will have dimensions 60 [cm] in X and 60 [cm] in Y and <200 [cm] in Z | ||
| Comments: | |||
| Record Date: 05/16/2025 17:04 | |||
| Identifier: | P-DET-ANC-ZDC.2 | WBS: | 6.10.11 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Approved | |
| Description: | ZDC system will have dimensions 60 [cm] in X and 60 [cm] in Y and <200 [cm] in Z (to be determined) | ||
| Comments: | |||
| Record Date: 05/15/2025 20:34 | |||
| Identifier: | P-DET-ANC-ZDC.2 | WBS: | |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | ||
| Description: | ZDC system will have dimensions 60 [cm] in X and 60 [cm] in Y and <200 [cm] in Z (to be determined) | ||
| Comments: | |||
| Record Date: 01/27/2025 16:43 | |||
| Identifier: | P-DET-ANC-ZDC.2 | WBS: | 6.10.11 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Approved | |
| Description: | ZDC system will have dimensions 60 [cm] in X and 60 [cm] in Y and <200 [cm] in Z (to be determined) | ||
| Comments: | |||
| Parents | |
| F-DET-ANC-ZDC.1 | ZDC will provide theta coverage in the range 0 < θ < 4 mrad (aperture limit, symmetric in phi). |
| F-DET-ANC-ZDC.6 | Must be compact enough to fit in the limited space allocated in the accelerator tunnel |
| Children | |
| No children. | |