Requirement Details
Electron Ion Collider

F-DET-ANC-ZDC.6
Requirement details, history, relationships and interfaces associated with requirement F-DET-ANC-ZDC.6
CURRENT RECORD
ARCHIVE RECORDS
RELATIONSHIPS
INTERFACES
| Record Date: 05/16/2025 17:04 | |||
| Identifier: | F-DET-ANC-ZDC.6 | WBS: | 6.10.11 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Approved | |
| Description: | Must be compact enough to fit in the limited space allocated in the accelerator tunnel | ||
| Comments: | |||
| Record Date: 05/15/2025 20:34 | |||
| Identifier: | F-DET-ANC-ZDC.6 | WBS: | |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | ||
| Description: | Must be compact enough to fit in the limited space allocated in the accelerator tunnel | ||
| Comments: | |||
| Record Date: 01/27/2025 16:43 | |||
| Identifier: | F-DET-ANC-ZDC.6 | WBS: | 6.10.11 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Approved | |
| Description: | Must be compact enough to fit in the limited space allocated in the accelerator tunnel | ||
| Comments: | |||
| Parents | |
| G-DET-ANC.4 | The EIC ancillary detectors will be functionally integrated with the other detectors, with the interaction region components, and with the facility infrastructure. |
| Children | |
| P-DET-ANC-ZDC.2 | ZDC system active area will have dimensions 60 [cm] in X and 60 [cm] in Y and <200 [cm] in Z |
This function not yet implemented.