Requirement Details
Electron Ion Collider
P-DET-ANC-ROMAN.2
Requirement details, history, relationships and interfaces associated with requirement P-DET-ANC-ROMAN.2
- CURRENT RECORD
- ARCHIVE RECORDS
- RELATIONSHIPS
- INTERFACES
Record Date: 10/10/2024 00:00 | |||
Identifier: | P-DET-ANC-ROMAN.2 | WBS: | 6.10.11 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | APPROVED | |
Description: | RPOT will have 2 layers per each station | ||
Comments: |
No archive versions
Parents | |
F-DET-ANC-ROMAN.1 | The Roman-Pots will provide coverage in the range 0.0* < θ < 5.0 mrad (? > 6) (*depends on beam optics, ca 10 sigma) |
Children | |
No children. |
This function not yet implemented.