Record Date: 10/10/2024 00:00 | |||
Identifier: | P-DET-ANC-ROMAN.1 | WBS: | 6.10.11 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | APPROVED | |
Description: | RPOT tracker will have granularity of 500um (pixels) with charge-sharing to achieve spatial resolution < 20um per hit. | ||
Comments: |
No archive versions
Parents | |
F-DET-ANC-ROMAN.3 | RPOT will provide good t-measurements of far-forward charged particles. |
Children | |
No children. |