Record Date: 01/27/2025 16:43 | |||
Identifier: | F-DET-ANC-OFFMO.1 | WBS: | 6.10.11 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | Approved | |
Description: | OFF-Momentum detectors will be placed as close as possible to the beam pipe (outside or inside of the vacuum) (to be verified). | ||
Comments: |
No archive versions
Parents | |
G-DET-ANC-OFFMO.1 | The Off-Momentum detectors should provide measurements of charged particles with different magnetic rigidity |
Children | |
P-DET-ANC-OFFMO.1 | OFFM tracker shall have granularity of 500um (pixels) with charge-sharing to achieve spatial resolution < 20um per hit. |
P-DET-ANC-OFFMO.2 | OFFM will have 2 layers per station |
P-DET-ANC-OFFMO.3 | OFFM will have 2 stations , separated by 2m |
P-DET-ANC-OFFMO.5 | OFFM tracker will have timing resolution X<35ps |
P-DET-ANC-OFFMO.4 | OFFM system dimensions will be 10[cm] in X and 20 [cm] in Y (to be determined) |
P-DET-ANC-OFFMO.8 | The OMDs need cooling of ~60 Watts per active layer, |