Description: | The PS must measure the energy and position of e+e- pairs from bremsstrahlung conversions. The direct photon CAL must measure the energy of the large bremsstrahlung flux while mitigating the high rates of background synchrotron radiation. | ||
Comments: |
No archive versions
Parents | |
G-DET.10 | The detector systems must fit within the available space in the experimental hall, and be consistent with the available infrastructure and resources. |
G-DET.9 | The detector and its sub-systems will be functionally integrated with one another, with the interaction region components, and with the facility infrastructure. |
G-DET.8 | The polarimetry and luminosity detectors shall measure the electron and proton beam polarization and monitor the instantaneous collision luminosities. |
G-DET-ANC-LUMI.1 | The luminosity system utilizes the bremsstrahlung process to provide measurements of the absolute luminosity to a precision of δL/L<= 1% and relative luminosity at 10^-4. |
Children | |
P-DET-ANC-LUMI.1 | The PS CAL energy resolution for electrons shall be s(E)/E < 15%/sqrt(E) . |
P-DET-ANC-LUMI.2 | The PS CALs, direct CAL, and trackers shall all provide timing resolution sufficient to resolve 10ns beam buckets |
P-DET-ANC-LUMI.3 | The PS CAL dimensions shall be 18 [cm] in X , 18 [cm] in Y, and 18 [cm] in Z |
P-DET-ANC-LUMI.4 | The PS CAL readout granularity shall be 3 [mm] in X, 3 [mm] in Y, and 3 [mm] in Z |
P-DET-ANC-LUMI.5 | The PS tracker dimensions shall cover the transverse face of the calorimeter with no acceptance gaps. |
P-DET-ANC-LUMI.6 | The direct photon CAL energy resolution for electrons shall be s(E)/E < 15%/sqrt(E). |
P-DET-ANC-LUMI.7 | The direct photon CAL dimensions is expected to be similar to the PS CAL |
P-DET-ANC-LUMI.8 | The direct photon CAL readout granularity is expecte to be more course grained than the PS CAL |