Requirement Details
Electron Ion Collider
F-DET-ANC-LOWQ2.3
Requirement details, history, relationships and interfaces associated with requirement F-DET-ANC-LOWQ2.3
- CURRENT RECORD
- ARCHIVE RECORDS
- RELATIONSHIPS
- INTERFACES
Record Date: 10/10/2024 00:00 | |||
Identifier: | F-DET-ANC-LOWQ2.3 | WBS: | 6.10.11 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | APPROVED | |
Description: | To measure the momentum of the scattered electron the Low-Q2 tagger will include a tracker. | ||
Comments: |
No archive versions
Parents | |
G-DET-ANC-LOWQ2.1 | The Low-Q2 detectors will measure the momentum of scattered electrons with Q2 below 0.1 GeV2 in the far-backward region. |
Children | |
P-DET-ANC-LOWQ2.2 | Each Low-Q2 station will have up to 4 silicon tracking layers |
P-DET-ANC-LOWQ2.3 | The Low-Q2 tracking system shall have a spatial resolution providing a momentum resolution < 5%. |
P-DET-ANC-LOWQ2.4 | Low- Q2 trackers shall provide timing resolution sufficient to resolve 10ns beam buckets |
P-DET-ANC-LOWQ2.5 | Low-Q2 trackers will have Q2 acceptance between 0 and 0.1 GeV2 |
P-DET-ANC-LOWQ2.12 | Low- Q2 tagger 1 calorimeter will have dimensions XX in X and XX in Y (to be determined) |
P-DET-ANC-LOWQ2.13 | Low- Q2 tagger 2 calorimeter will have dimensions XX in X and XX in Y (to be determined) |
This function not yet implemented.