Record Date: 02/13/2025 19:28 | |||
Identifier: | F-DET-ANC-LOWQ2.3 | WBS: | 6.10.11 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | Approved | |
Description: | To measure the momentum of the scattered electron the Low-Q² tagger will include a tracker. | ||
Comments: |
Record Date: 01/27/2025 16:43 | |||
Identifier: | F-DET-ANC-LOWQ2.3 | WBS: | 6.10.11 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | Approved | |
Description: | To measure the momentum of the scattered electron the Low-Q2 tagger will include a tracker. | ||
Comments: |
Parents | |
G-DET-ANC-LOWQ2.1 | The Low-Q² detectors will measure the momentum of scattered electrons with Q² below 0.1 GeV² in the far-backward region. |
Children | |
P-DET-ANC-LOWQ2.2 | Each Low-Q2 station will have up to 4 silicon tracking layers |
P-DET-ANC-LOWQ2.3 | The Low-Q2 tracking system shall have a spatial resolution providing a momentum resolution < 5%. |
P-DET-ANC-LOWQ2.4 | Low- Q² trackers shall provide timing resolution sufficient to resolve 10ns beam buckets |
P-DET-ANC-LOWQ2.12 | Low- Q² tagger 1 calorimeter will have dimensions XX in X and XX in Y (to be determined) |
P-DET-ANC-LOWQ2.5 | Low-Q² trackers will have Q² acceptance between 0 and 0.1 GeV² |
P-DET-ANC-LOWQ2.13 | Low- Q² tagger 2 calorimeter will have dimensions XX in X and XX in Y (to be determined) |