Requirement Details
Electron Ion Collider
F-DET-ANC-LOWQ2.1
Requirement details, history, relationships and interfaces associated with requirement F-DET-ANC-LOWQ2.1
- CURRENT RECORD
- ARCHIVE RECORDS
- RELATIONSHIPS
- INTERFACES
Record Date: 11/01/2023 00:00 | |||
Identifier: | F-DET-ANC-LOWQ2.1 | WBS: | 6.10.11 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | APPROVED | |
Description: | The acceptance for the low-Q2 tagger should complement the central detector to reach the coverage close to the limits given by the divergence of the beam and beamline magnets. | ||
Comments: |
No archive versions
Parents | |
G-DET-ANC-LOWQ2.1 | The Low-Q2 detectors will measure the momentum of scattered electrons with Q2 below 0.1 GeV2 in the far-backward region. |
Children | |
P-DET-ANC-LOWQ2.1 | Low-Q2 will have one or more tagger stations to cover the maximum momentum acceptance |
P-DET-ANC-LOWQ2.4 | Low- Q2 trackers shall provide timing resolution sufficient to resolve 10ns beam buckets |
P-DET-ANC-LOWQ2.5 | Low-Q2 trackers will have Q2 acceptance between 0 and 0.1 GeV2 |
This function not yet implemented.