Requirement Details
Electron Ion Collider
F-DET-ANC-B0.2
Requirement details, history, relationships and interfaces associated with requirement F-DET-ANC-B0.2
CURRENT RECORD
ARCHIVE RECORDS
RELATIONSHIPS
INTERFACES
Record Date: 05/16/2025 17:04 | |||
Identifier: | F-DET-ANC-B0.2 | WBS: | 6.10.11 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | Approved | |
Description: | B0-system shall provide theta coverage in the range 5.5 < θ < 20.0 mrad (4.6 < ƞ < 5.9) with respect to the hadron beam line. | ||
Comments: |
Record Date: 05/15/2025 20:34 | |||
Identifier: | F-DET-ANC-B0.2 | WBS: | |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | ||
Description: | B0-system shall provide theta coverage in the range 5.5 < θ < 20.0 mrad (4.6 < ƞ < 5.9) with respect to the hadron beam line. | ||
Comments: |
Record Date: 02/13/2025 19:28 | |||
Identifier: | F-DET-ANC-B0.2 | WBS: | 6.10.11 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | Approved | |
Description: | B0-system shall provide theta coverage in the range 5.5 < θ < 20.0 mrad (4.6 < ƞ < 5.9) with respect to the hadron beam line. | ||
Comments: |
Record Date: 01/27/2025 16:43 | |||
Identifier: | F-DET-ANC-B0.2 | WBS: | 6.10.11 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | Approved | |
Description: | B0-system shall provide theta coverage in the range 5.5 < θ < 20.0 mrad (4.6 < η < 5.9) with respect to the hadron beam line. | ||
Comments: |
Parents | |
G-DET-ANC-B0.2 | The B0-system will tag protons at higher angles (especially important for lower beam energies). |
Children | |
P-DET-ANC-B0.6 | B0 tracker shall provide momentum resolution < 6%. |
P-DET-ANC-B0.5 | B0 tracker dimensions shall be 24 [cm] in X and 30 [cm] in Y |
P-DET-ANC-B0.7 | B0 calorimeter dimensions shall be 24 [cm] in X and 30 [cm] in Y |
This function not yet implemented.