Record Date: 10/10/2024 00:00 | |||
Identifier: | F-DET-ANC-B0.1 | WBS: | 6.10.11 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | APPROVED | |
Description: | Silicon detector with sufficient timing and spatial resolution will provide tracking measurements of the charged particles in the hadron-outgoing direction. | ||
Comments: |
No archive versions
Parents | |
G-DET-ANC-B0.1 | The B0 system will provide measurements of charged particles in the forward directions. |
Children | |
P-DET-ANC-B0.1 | B0 tracker shall have a pixel granularity < XX (to be determined) |
P-DET-ANC-B0.2 | B0 tracker shall have a timing resolution < XX (to be determined) |
P-DET-ANC-B0.3 | B0- tracker shall have at least 4 layers |