HIN : HSR Hadron Ring Injection System (WBS 6.02.03)
- 6.02.03The HSR injection line magnets excluding the induction septum shall provide a half physical aperture greater than 6σ for the injected beam.10/12/2026ApprovedFALSE
- 6.02.03The HSR induction septum shall provide a half physical aperture greater than 5σ for the injected beam.10/12/2026ApprovedFALSE
- 6.02.03The HSR induction septum shall provide a half physical aperture greater than 6σ for the circulating beam.10/12/2026ApprovedFALSE
- 6.02.03The HSR Injection line shall have a temporary beam dump for commissioning with the same requirements as the existing W-line beam dump.10/12/2026ApprovedFALSE
- 6.02.03The HSR Injection line shall have strategically placed beam dump for machine protection, commissioning and diagnostics as required.10/12/2026ApprovedFALSE
- HIN EXTERNALSRequirements who's parents are in other sub-systems.
- 6.02.03The HSR injection system shall utilize the existing RHIC injector chain upstream of the RHIC-ATR D26 Dipole magnet with no modifications.10/12/2026ApprovedFALSE
- 6.02.03The HSR injection system, consisting of the transport beamline, septum magnet and injection kickers, shall be capable of transporting a maximum beam rigidity of 81.12Tm from the transport line to IR4 central area and injecting it into the HSR.10/12/2026ApprovedFALSE
- 6.02.03The HSR Injection System design shall use a warm transport line in arc 6-4 as continuation of the Injection line to transport the hadron beam to the injection system located in IR4.10/12/2026ApprovedFALSE
- 6.02.03The HSR injection transport beamline shall be able to transport polarized beam with less than 5% polarization loss.10/12/2026ApprovedFALSE
- 6.02.03The HSR injection system shall be able to inject all beam species with less than 5% beam emittance increase.10/12/2026ApprovedFALSE
- 6.02.03The HSR injection system shall be able to fill the HSR with 290 consecutive bunches without interruption.10/12/2026ApprovedFALSE
- 6.02.03The HSR injection system shall be able to fill the HSR with one(1) bunch per AGS cycle for polarized proton, two(2) bunches per AGS cycle for ion beams.10/12/2026ApprovedFALSE
- 6.02.03The HSR injection system transfer line shall provide the following physical aperture:10/12/2026ApprovedFALSE
- 6.02.03The operational availability design target for the HSR Injection System shall be consistent with the operational availability target for the overall EIC as set forth in Electron-Ion Collider Global Requirements. Refer to [EIC-ORG-PLN-010].10/12/2026ApprovedFALSE
- 6.02.03The HSR Injection system transport line shall be modified to add septum magnets in the Q3-Q4 warm straight section of the HSR on 4 o’clock side of the IR4 for hadron beam transfer into the HSR beam pipe.10/12/2026ApprovedFALSE
HIN-MAG : HSR Hadron Ring Injection Magnets (WBS 6.02.03.03)
- 6.02.03The HSR injection system shall have two septa, one DC septum and one induction septum.10/12/2026ApprovedFALSE
- 6.02.03The septa of HSR injection system shall provide a total bending angle of 69 (mrad).10/12/2026ApprovedFALSE
- HIN-MAG EXTERNALSRequirements who's parents are in other sub-systems.
- 6.02.03Any reused existing RHIC-ATR transfer line magnets shall meet the requirements of the new approved HSR Injection line lattice.10/12/2026ApprovedFALSE
- 6.02.03New magnets shall only be used where any available existing magnets do not meet the requirements of the new approved HSR Injection line lattice.10/12/2026ApprovedFALSE
HIN-MAG-GRST : HSR Hadron Ring Injection Magnet Girders (WBS 6.02.02.03.03)
- 6.02.02.03.03Within a girder, the as-installed magnet-to-magnet alignment shall be +/-400 (µm) in horizontal and vertical after installation and smoothing.10/12/2026ApprovedFALSE
- 6.02.02.03.03The first natural frequency of the installed magnet–girder assembly (movers locked) shall be ≥ 20 (Hz).10/12/2026ApprovedFALSE
- 6.02.02.03.03The natural frequency of the installed magnet–girder assembly (movers locked) shall be avoid 60 (Hz).10/12/2026ApprovedFALSE
- 6.02.02.03.03The girder alighment mechanism shall provide a minimum roll and pitch range of ± 200 (µrad) .10/12/2026ApprovedFALSE
- 6.02.02.03.03The girder assembly and its anchors shall be designed and anchored in accordance with ASCE/SEI 7 using the Site Design Spectral Acceleration (SDS) and S1 parameters. Under the Operating Basis Earthquake (OBE), the assembly shall require no repositioning. Under the Safe Shutdown Earthquake (SSE), the assembly shall experience no structural failure, and any residual misalignment shall be recoverable within the installed alighnment range.10/12/2026ApprovedFALSE
- 6.02.02.03.03Ancillary equipment on/near the girder shall be mechanically isolated via compliant brackets and service loops, maintain clearances to fiducials/adjusters and be included in modal/vibration analysis.10/12/2026ApprovedFALSE
- 6.02.02.03.03Piping (process/cooling/cryo) and electrical conduits/trays shall be supported by dedicated, isolated brackets, maintain clearances to fiducials/adjusters and be included in modal/vibration analysis.10/12/2026ApprovedFALSE
- 6.02.02.03.03The girder body material shall be construted of material that provides high damping and stiffness with corrosion-protected per tunnel environment.10/12/2026ApprovedFALSE
- 6.02.02.03.03The girder assembly, including leveling screws, top plates, and anchors, shall support the total installed service mass under worst-case operating load.10/12/2026ApprovedFALSE
- 6.02.02.03.03The girder rigging features (lift eyes, CG marks) shall be provided and proof-load tested at 1.25× lifted mass.10/12/2026ApprovedFALSE
- 6.02.02.03.03The girder shall be designed for a minimum service life of 30 years, accounting for creep, fatigue, and corrosion.10/12/2026ApprovedFALSE
HIN-MAG-DV1 : HSR Injector Magnet D1 (WBS 6.02.03.03.01)
- 6.02.03.03.01The magnet shall use am existing refurbished ATR DV1 dipole to provide a a single function vertical bending dipole field centered on the injected beam axis.10/12/2026ApprovedFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.01The physical length of the magnet shall be less than or equal to 1(m)10/12/2026ApprovedFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.01The magnet shall be able to fit within the following volume constraints:10/12/2026ApprovedFALSE
- 6.02.03.03.01The magnet volume occupied shall be approved by the EIC engineering team to ensure the design does not impede any other EIC components or block egress.10/12/2026ApprovedFALSE
- 6.02.03.03.01The magnet field axis displacement and rotational alignment shall utilize the existing fiducials to determine the field center and rotational alignment.10/12/2026ApprovedFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.01The Integrated Dipole Field B.L Shall be = 0.14™10/12/2026ApprovedFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.01The magnet cryostat installation position and alignment with respect to the nominal beam position defined in the lattice file and axis shall be within the following limits:(Note: Z is along the beam axis)10/12/2026ApprovedFALSE
- 6.02.03.03.01The magnet install center displacement shall be aligned with respect to the specified lattice field center position dx=+/-300(um) dy=+/-300(um) dz= +/-710(um)10/12/2026ApprovedFALSE
- 6.02.03.03.01The magnet rotational alignment shall be aligned with respect to the specified lattice beam axis About X=+/-0.3(mrad) About Y=+/-0.3(mrad) About Z=+/-0.15(mrad)10/12/2026ApprovedFALSE
- 6.02.03.03.01These are existing magnets, the magnet bore field should have the same multipole content as per the existing data. If the magnet needs to be repositioned it is assumed the field quality of the bore remains unchanged.10/12/2026ApprovedFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.01The magnet cooling system shall be capable of maintaning an operational temperature range of +25 (C) to +35 (C).10/12/2026ApprovedFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.01The magnet coils shall pass a Hi-Pot test at 1(kV) at 10(uA).10/12/2026ApprovedFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.0110/12/2026Not ApplicableFALSE
- 6.02.03.03.01The magnet shall be able to sustain 30 years of EIC operation under nominal conditions.During this time the magnet is expected to survive 30000 power cycles.10/12/2026ApprovedFALSE
- 6.02.03.03.01Over its planned life of 30(yrs), the magnet Shall be able to survive a total integrated absorbed radiation dose from 1(MGy) to 20(MGy) without damage.The upper limit should be taken as a guide for the design process. The actual upper limit the magnet will see in operation will need further analysis and will need to be confirmed by the EIC radiation physics team10/12/2026ApprovedFALSE
HIN-MAG-DW0 : HSR Injector Magnet D2 (WBS 6.02.03.03.01)
- 6.02.03.03.01The magnet shall use an existingnew HSR DW0 dipole to porvide a single function horizontal bending dipole field centered on the injected beam axis which directs the injected beam to merge with the circulating beam .10/12/2026ApprovedFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- The magnet field axis displacement and rotational alignment shall utilize the existing fiducials to determine the field center and rotational alignment.10/12/2026ApprovedFALSE
- The magnetic field axis displacement tolerances: The field center shall be identified to within dx=+/-0.3(mm) dy=+/-0.3(mm) dz=+/-0.71(mm)10/12/2026ApprovedFALSE
- The magnetic field rotational alignment tolerances: The field axes shall be identified to within the following rotational tolerances About X=+/-0.15(mrad) About Y=+/-0.15(mrad) About Z=+/-0.15(mrad)10/12/2026ApprovedFALSE
- This is an utlizes a new DW0 magnet the magnet bore field should have the same multipole content as per the DW0 design.10/12/2026ApprovedFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
HIN-MAG-CHV1 : HSR Injector Magnet Ver Corr (WBS 6.02.03.03.02)
- 6.02.03.03.02The magnet shall use the existing ATR vertical and horizontal correctors to create a dual plane corrector by placing the horizontal and vertical correctors, consecutively with both correctors centered on the injected beam axis.10/12/2026ApprovedFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.02The physical length of the combined corrector magnet should be ~ 0.82(m) because each existing single plane corrector is <0.41(m).10/12/2026ApprovedFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.02The magnet shall have a gap capable of accommodating a beampipe with an OD of 72(mm)10/12/2026ApprovedFALSE
- 6.02.03.03.02The magnet shall be able to fit within the following volume constraints:10/12/2026ApprovedFALSE
- 6.02.03.03.02The magnet volume occupied shall be approved by the EIC engineering team to ensure the design does not impede any other EIC components or block egress.10/12/2026ApprovedFALSE
- 6.02.03.03.02The magnet field axis displacement and rotational alignment shall utilize the existing fiducials to determine the field center and rotational alignment.10/12/2026ApprovedFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.02The Integrated Dipole Field B.L Shall be =30(mT.m) in either plane.10/12/2026ApprovedFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.02The magnet cryostat installation position and alignment with respect to the nominal beam position defined in the lattice file and axis shall be within the following limits:(Note: Z is along the beam axis)10/12/2026ApprovedFALSE
- 6.02.03.03.02The magnet install center shall be aligned with respect to the specified lattice field center position within. dx=+/-300(um) dy=+/-300(um) dz= +/-710(um)10/12/2026ApprovedFALSE
- 6.02.03.03.02The magnet rotational alignment shall be aligned with respect to the specified lattice beam axis to within About X=+/-0.37(mRad) About Y=+/-0.37(mRad) About Z=+/-0.15(mRad)10/12/2026ApprovedFALSE
- 6.02.03.03.02These are existing magnets; the magnet bore field should have the same multipole content as per the existing magnet. If the magnet needs to be repositioned it is assumed the field quality of the bore remains unchanged10/12/2026ApprovedFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.02The magnet cooling system shall be capable of maintaning an operational temperature range of +25 (C) to +35 (C).10/12/2026ApprovedFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.02The magnet coils shall pass a Hi-Pot test at 1(kV) at 10(uA).10/12/2026ApprovedFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.02The magnet shall be able to sustain 30 years of EIC operation under nominal conditions.During this time the magnet is expected to survive 30000 power cycles.10/12/2026ApprovedFALSE
- 6.02.03.03.02Over its planned life of 30(yrs), the magnet Shall be able to survive a total integrated absorbed radiation dose from 1(MGy) to 20(MGy) without damage.The upper limit should be taken as a guide for the design process. The actual upper limit the magnet will see in operation will need further analysis and will need to be confirmed by the EIC radiation physics team10/12/2026ApprovedFALSE
HIN-MAG-CHV2 : HSR Injector Magnet DVERT_1 (WBS 6.02.03.03.02)
- 6.02.03.03.02The magnet shall have a dual plane corrector with a combined dual function horizontal bending dipole corrector and a vertically bending dipole field both centered on the injected beam axis. Both planes must be capable of simultaneous operation.10/12/2026ApprovedFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.02The physical length of the magnet shall be less than or equal to <0.8(m). This assumes a magnet yolk of ~0.4(m) with a 0.2(m) drift space on either side.10/12/2026ApprovedFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.02The magnet shall have a gap of 114(mm)10/12/2026ApprovedFALSE
- 6.02.03.03.02The magnet shall be able to fit within the following volume constraints:10/12/2026ApprovedFALSE
- 6.02.03.03.02The magnet volume occupied shall be approved by the EIC engineering team to ensure the design does not impede any other EIC components or block egress.10/12/2026ApprovedFALSE
- 6.02.03.03.02The magnet field axis displacement and rotational alignment shall be identified by applying fiducials to locate the field center and rotational alignment of the magnet, within the following limits.10/12/2026ApprovedFALSE
- 6.02.03.03.02The magnet install center shall be aligned with respect to the specified lattice field center position within. dx=+/-300(um) dy=+/-300(um) dz= +/-710(um)10/12/2026ApprovedFALSE
- 6.02.03.03.02The magnet rotational alignment shall be aligned with respect to the specified lattice beam axis to within About X=+/-0.37(mRad) About Y=+/-0.37(mRad) About Z=+/-0.15(mRad)10/12/2026ApprovedFALSE
- 6.02.03.03.02The integrated dipole Field B in both planes of the corrector Shall be = 0.025(T.m)10/12/2026ApprovedFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.02The magnet installation position and alignment with respect to the nominal beam position defined in the lattice file and axis shall be within the following limits:(Note: Z is along the beam axis)10/12/2026ApprovedFALSE
- 6.02.03.03.02The magnet install center displacement shall be aligned with respect to the specified lattice field center position dx=+/-300(um) dy=+/-300(um) dz= +/-710(um)10/12/2026ApprovedFALSE
- 6.02.03.03.02The magnet rotational alignment shall be aligned with respect to the specified lattice beam axis About X=+/-0.37 (mrad) About Y=+/-0.37 (mrad) About Z=+/-0.15 (mrad)10/12/2026ApprovedFALSE
- 6.02.03.03.02The magnet field homogeneity shall be measured within the following constraints:10/12/2026ApprovedFALSE
- 6.02.03.03.02The magnet field homogeneity shall be measured at a reference radius of 25(mm)10/12/2026ApprovedFALSE
- 6.02.03.03.02The magnet field homogeneity shall be measured at a reference field comparable to the nominal operating field of the magnet.10/12/2026ApprovedFALSE
- 6.02.03.03.02The magnet bore field Shall have the following multipole content Notes: The units are specified in parts of 10-4 of the main components.10/12/2026ApprovedFALSE
- 6.02.03.03.02Horizontal corrector on; b1=10000, a1=0 Vertical corrector on; b1=0, a1=1000010/12/2026ApprovedFALSE
- 6.02.03.03.02Either plane powered; b2 < +/-100, a2< +/-10010/12/2026ApprovedFALSE
- 6.02.03.03.02Either plane powered; b3 < +/-100, a3 < +/-10010/12/2026ApprovedFALSE
- 6.02.03.03.02Either plane powered; b4 < +/-100, a4 < +/-10010/12/2026ApprovedFALSE
- 6.02.03.03.02Either plane powered; b5 < +/-100, a5 < +/-10010/12/2026ApprovedFALSE
- 6.02.03.03.02Either plane powered; b6 < +/-100, a6 < +/-10010/12/2026ApprovedFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.02The magnet cooling system shall be capable of maintaning an operational temperature range of +25 (C) to +35 (C).10/12/2026ApprovedFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.02The magnet coils shall pass a Hi-Pot test of 5(kV) at 10(uA).10/12/2026ApprovedFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.0210/12/2026Not ApplicableFALSE
- 6.02.03.03.02The magnet shall be able to sustain 30 years of EIC operation under nominal conditions.During this time the magnet is expected to survive 30000 power cycles.10/12/2026ApprovedFALSE
- 6.02.03.03.02Over its planned life of 30(yrs), the magnet Shall be able to survive a total integrated absorbed radiation dose from 1(MGy) to 20(MGy) without damage.The upper limit should be taken as a guide for the design process. The actual upper limit the magnet will see in operation will need further analysis and will need to be confirmed by the EIC radiation physics team10/12/2026ApprovedFALSE
HIN-MAG-Q:100 : HSR Injector Magnet Q2 (WBS 6.02.03.03.03)
- The magnet shall provide a single function normal quadrupole field centered on the injected beam axis.10/12/2026ApprovedFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- The physical length of the magnet shall be less than or equal to <1.8(m). This assumes a magnet yolk of ~1(m) with a 0.4(m) drift space on either side.10/12/2026ApprovedFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- The magnet shall have a pole tip radius capable of accommodating a beampipe with an OD of 72(mm)10/12/2026ApprovedFALSE
- 10/12/2026Not ApplicableFALSE
- The magnet shall be able to fit within the following volume constraints:10/12/2026ApprovedFALSE
- The magnet volume occupied shall be approved by the EIC engineering team to ensure the design does not impede any other EIC components or block egress.10/12/2026ApprovedFALSE
- The magnet field axis displacement and rotational alignment shall be identified by applying fiducials to locate the field center and rotational alignment of the magnet, within the following limits.10/12/2026ApprovedFALSE
- The magnetic field axis displacement tolerances: The field center shall be identified to within dx=+/-100(um) dy=+/-100(um) dz=+/-750(um)10/12/2026ApprovedFALSE
- The magnetic field rotational alignment tolerances: The field axes shall be identified to within the following rotational tolerances About X=+/-0.15(mrad) About Y=+/-0.15(mrad) About Z=+/-0.15(mrad)10/12/2026ApprovedFALSE
- 10/12/2026Not ApplicableFALSE
- The Integrated Gradient Field G Shall be = 20.47(T)10/12/2026ApprovedFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- The magnet cryostat installation position and alignment with respect to the nominal beam position defined in the lattice file and axis shall be within the following limits:(Note: Z is along the beam axis)10/12/2026ApprovedFALSE
- The magnet install center displacement shall be aligned with respect to the specified lattice field center position dx=+/-100(um) dy=+/-100(um) dz= +/-750(um)10/12/2026ApprovedFALSE
- The magnet rotational alignment shall be aligned with respect to the specified lattice beam axis About X=+/-0.15(mrad) About Y=+/-0.15(mrad) About Z=+/-0.15(mrad)10/12/2026ApprovedFALSE
- The magnet field homogeneity shall be measured within the following constraints:10/12/2026ApprovedFALSE
- The magnet field homogeneity shall be measured at a reference radius of 25(mm)10/12/2026ApprovedFALSE
- The magnet field homogeneity shall be measured at a reference field comparable to the nominal operating field of the magnet.10/12/2026ApprovedFALSE
- The magnet bore field Shall have the following multipole content Notes: The units are specified in parts of 10-4 of the main components.10/12/2026ApprovedFALSE
- 10/12/2026Not ApplicableFALSE
- b2 = 10000 , a2 = +/-1010/12/2026ApprovedFALSE
- b3 < +/- 10 , a3 < +/- 1010/12/2026ApprovedFALSE
- b4 < +/- 10 , a4 < +/-1010/12/2026ApprovedFALSE
- b5 < +/- 10 , a5 < +/- 1010/12/2026ApprovedFALSE
- b6 < +/- 10 , a6 < +/- 1010/12/2026ApprovedFALSE
- b7 < +/- 10 , a7 < +/- 1010/12/2026ApprovedFALSE
- b8 < +/- 10 , a8 < +/- 1010/12/2026ApprovedFALSE
- b9 < +/- 10 , a9 < +/- 1010/12/2026ApprovedFALSE
- b10 < +/- 10 , a10 < +/- 1010/12/2026ApprovedFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- The magnet cooling system shall be capable of maintaning an operational temperature range of +25 (C) to +35 (C).10/12/2026ApprovedFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- The magnet coils shall pass a Hi-Pot test of 5(kV) at 10(uA).10/12/2026ApprovedFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- The magnet shall be able to sustain 30 years of EIC operation under nominal conditions.During this time the magnet is expected to survive 30000 power cycles.10/12/2026ApprovedFALSE
- Over its planned life of 30(yrs), the magnet Shall be able to survive a total integrated absorbed radiation dose from 1(MGy) to 20(MGy) without damage.The upper limit should be taken as a guide for the design process. The actual upper limit the magnet will see in operation will need further analysis and will need to be confirmed by the EIC radiation physics team10/12/2026ApprovedFALSE
HIN-MAG-QD1 : HSR Injector Magnet QD1 (WBS 6.02.03.03.03)
- 6.02.03.03.03The magnet shall use an existing ATR combined function magnet to provide a combined function horizontal bending dipole field and a normal quadrupole field centered on the injected beam axis.10/12/2026ApprovedFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.03The physical length of the magnet shall be less than or equal to <3.66(m)10/12/2026ApprovedFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.03The magnet shall have a gap capable of accommodating a rectangular beampipe, width 165(mm), height 32(mm).10/12/2026ApprovedFALSE
- 6.02.03.03.03The magnet shall be able to fit within the following volume constraints:10/12/2026ApprovedFALSE
- 6.02.03.03.03The magnet volume occupied shall be approved by the EIC engineering team to ensure the design does not impede any other EIC components or block egress.10/12/2026ApprovedFALSE
- 6.02.03.03.03The magnet field axis displacement and rotational alignment shall utilize the existing fiducials to determine the field center and rotational alignment.10/12/2026ApprovedFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.03The Integrated Dipole Field B.L Shall be = 4.8(T.m)10/12/2026ApprovedFALSE
- 6.02.03.03.03The Integrated Gradient Field G.L Shall be = 13.93(T)10/12/2026ApprovedFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.03The magnet installation position and alignment with respect to the nominal beam position defined in the lattice file and axis shall be within the following limits:(Note: Z is along the beam axis)10/12/2026ApprovedFALSE
- 6.02.03.03.03The magnet install center displacement shall be aligned with respect to the specified lattice field center position dx=+/-100(um) dy=+/-100(um) dz= +/-710(um)10/12/2026ApprovedFALSE
- 6.02.03.03.03The magnet rotational alignment shall be aligned with respect to the specified lattice beam axis About X=+/-0.03(mrad) About Y=+/-0.03(mrad) About Z=+/-0.15mrad)10/12/2026ApprovedFALSE
- 6.02.03.03.03This is an existing magnet the magnet bore field should have the same multipole content as per the existing combined function ATR magnets. If the magnet needs to be repositioned it shall be confirmed the field quality of the bore remains unchanged.10/12/2026ApprovedFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.03The magnet cooling system shall be capable of maintaning an operational temperature range of +25 (C) to +35 (C).10/12/2026ApprovedFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.03The magnet coils shall pass a Hi-Pot test at 1(kV) at 10(uA).10/12/2026ApprovedFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.03The magnet shall be able to sustain 30 years of EIC operation under nominal conditions.During this time the magnet is expected to survive 30000 power cycles.10/12/2026ApprovedFALSE
- 6.02.03.03.03Over its planned life of 30(yrs), the magnet Shall be able to survive a total integrated absorbed radiation dose from 1(MGy) to 20(MGy) without damage.The upper limit should be taken as a guide for the design process. The actual upper limit the magnet will see in operation will need further analysis and will need to be confirmed by the EIC radiation physics team10/12/2026ApprovedFALSE
HIN-MAG-QD2 : HIN Quadrupole Magnet (QD2) (WBS 6.02.03.03.03)
- 6.02.03.03.03The magnet shall use an existing ATR combined function magnet to provide a combined function horizontal bending dipole field and a normal quadrupole field centered on the injected beam axis.10/12/2026ApprovedFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.03The physical length of the magnet shall be less than or equal to <2.95(m)10/12/2026ApprovedFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.03The magnet shall have a gap capable of accommodating a beampipe with an OD of 36(mm)10/12/2026ApprovedFALSE
- 6.02.03.03.03The magnet shall be able to fit within the following volume constraints:10/12/2026ApprovedFALSE
- 6.02.03.03.03The magnet volume occupied shall be approved by the EIC engineering team to ensure the design does not impede any other EIC components or block egress.10/12/2026ApprovedFALSE
- 6.02.03.03.03The magnet field axis displacement and rotational alignment shall utilize the existing fiducials to determine the field center and rotational alignment.10/12/2026ApprovedFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.03The Integrated Dipole Field B.L Shall be = 3.88 (T.m)10/12/2026ApprovedFALSE
- 6.02.03.03.03The Integrated Gradient Field G.L Shall be = 11.22(T)10/12/2026ApprovedFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.03The magnet installation position and alignment with respect to the nominal beam position defined in the lattice file and axis shall be within the following limits:(Note: Z is along the beam axis)10/12/2026ApprovedFALSE
- 6.02.03.03.03The magnet install center displacement shall be aligned with respect to the specified lattice field center position dx=+/-100(um) dy=+/-100(um) dz= +/-710(um)10/12/2026ApprovedFALSE
- 6.02.03.03.03The magnet rotational alignment shall be aligned with respect to the specified lattice beam axis About X=+/-0.03(mrad) About Y=+/-0.03(mrad) About Z=+/-0.15mrad)10/12/2026ApprovedFALSE
- 6.02.03.03.03This is an existing magnet the magnet bore field should have the same multipole content as per the existing combined function ATR magnets. If the magnet needs to be repositioned it shall be confirmed the field quality of the bore remains unchanged.10/12/2026ApprovedFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.03The magnet cooling system shall be capable of maintaning an operational temperature range of +25 (C) to +35 (C).10/12/2026ApprovedFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.03The magnet coils shall pass a Hi-Pot test at 1(kV) at 10(uA).10/12/2026ApprovedFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.03The magnet shall be able to sustain 30 years of EIC operation under nominal conditions.During this time the magnet is expected to survive 30000 power cycles.10/12/2026ApprovedFALSE
- 6.02.03.03.03Over its planned life of 30(yrs), the magnet Shall be able to survive a total integrated absorbed radiation dose from 1(MGy) to 20(MGy) without damage.The upper limit should be taken as a guide for the design process. The actual upper limit the magnet will see in operation will need further analysis and will need to be confirmed by the EIC radiation physics team10/12/2026ApprovedFALSE
HIN-MAG-QLA:100 : HSR Injector Magnet Q3 (WBS 6.02.03.03.03)
- The magnet shall provide a single function normal quadrupole field centered on the injected beam axis.10/12/2026ApprovedFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- The physical length of the magnet shall be less than or equal to <1.8(m). This assumes a magnet yolk of ~1(m) with a 0.4(m) drift space on either side.10/12/2026ApprovedFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- The magnet shall have a pole tip radius capable of accommodating a beampipe with associated bake out heaters having a total OD of 114(mm)10/12/2026ApprovedFALSE
- 10/12/2026Not ApplicableFALSE
- The magnet shall be able to fit within the following volume constraints:10/12/2026ApprovedFALSE
- The magnet volume occupied shall be approved by the EIC engineering team to ensure the design does not impede any other EIC components or block egress.10/12/2026ApprovedFALSE
- The magnet field axis displacement and rotational alignment shall be identified by applying fiducials to locate the field center and rotational alignment of the magnet, within the following limits.10/12/2026ApprovedFALSE
- The magnetic field axis displacement tolerances: The field center shall be identified to within dx=+/-100(um) dy=+/-100(um) dz=+/-750(um)10/12/2026ApprovedFALSE
- The magnetic field rotational alignment tolerances: The field axes shall be identified to within the following rotational tolerances About X=+/-0.15(mrad) About Y=+/-0.15(mrad) About Z=+/-0.15(mrad)10/12/2026ApprovedFALSE
- 10/12/2026Not ApplicableFALSE
- The Integrated Gradient Field G Shall be = 13.48(T)10/12/2026ApprovedFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- The magnet installation position and alignment with respect to the nominal beam position defined in the lattice file and axis shall be within the following limits:(Note: Z is along the beam axis)10/12/2026ApprovedFALSE
- The magnet install center displacement shall be aligned with respect to the specified lattice field center position dx=+/-100(um) dy=+/-100(um) dz= +/-750(um)10/12/2026ApprovedFALSE
- The magnet rotational alignment shall be aligned with respect to the specified lattice beam axis About X=+/-0.15(mrad) About Y=+/-0.15(mrad) About Z=+/-0.15(mrad)10/12/2026ApprovedFALSE
- The magnet field homogeneity shall be measured within the following constraints:10/12/2026ApprovedFALSE
- The magnet field homogeneity shall be measured at a reference radius of 36(mm)10/12/2026ApprovedFALSE
- The magnet field homogeneity shall be measured at a reference field comparable to the nominal operating field of the magnet.10/12/2026ApprovedFALSE
- The magnet bore field Shall have the following multipole content Notes: The units are specified in parts of 10-4 of the main components.10/12/2026ApprovedFALSE
- 10/12/2026Not ApplicableFALSE
- b2 = 10000 , a2 = +/-1010/12/2026ApprovedFALSE
- b3 < +/- 10 , a3 < +/- 1010/12/2026ApprovedFALSE
- b4 < +/- 10 , a4 < +/-1010/12/2026ApprovedFALSE
- b5 < +/- 10 , a5 < +/- 1010/12/2026ApprovedFALSE
- b6 < +/- 10 , a6 < +/- 1010/12/2026ApprovedFALSE
- b7 < +/- 10 , a7 < +/- 1010/12/2026ApprovedFALSE
- b8 < +/- 10 , a8 < +/- 1010/12/2026ApprovedFALSE
- b9 < +/- 10 , a9 < +/- 1010/12/2026ApprovedFALSE
- b10 < +/- 10 , a10 < +/- 1010/12/2026ApprovedFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- The magnet cooling system shall be capable of maintaning an operational temperature range of +25 (C) to +35 (C).10/12/2026ApprovedFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- The magnet coils shall pass a Hi-Pot test of 5(kV) at 10(uA).10/12/2026ApprovedFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- The magnet shall be able to sustain 30 years of EIC operation under nominal conditions.During this time the magnet is expected to survive 30000 power cycles.10/12/2026ApprovedFALSE
- Over its planned life of 30(yrs), the magnet Shall be able to survive a total integrated absorbed radiation dose from 1(MGy) to 20(MGy) without damage.The upper limit should be taken as a guide for the design process. The actual upper limit the magnet will see in operation will need further analysis and will need to be confirmed by the EIC radiation physics team10/12/2026ApprovedFALSE
HIN-MAG-YQ1 : HIN Quadrupole Magnet (YQ1) (WBS 6.02.03.03.03)
- 6.02.03.03.03The magnet shall use an existing refurbished ATR YQ1 quadrupole to provide a single function normal quadrupole field centered on the injected beam axis.10/12/2026ApprovedFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.03The physical length of the magnet shall be less than or equal to <0.73(m)10/12/2026ApprovedFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.03The magnet shall have a gap capable of accommodating a beampipe with an OD of 72(mm)10/12/2026ApprovedFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.03The magnet shall be able to fit within the following volume constraints:10/12/2026ApprovedFALSE
- 6.02.03.03.03The magnet volume occupied shall be approved by the EIC engineering team to ensure the design does not impede any other EIC components or block egress.10/12/2026ApprovedFALSE
- 6.02.03.03.03The magnet field axis displacement and rotational alignment shall utilize the existing fiducials to determine the field center and rotational alignment.10/12/2026ApprovedFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.03The Integrated Gradient Field G Shall be = 12.11(T)10/12/2026ApprovedFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.03The magnet cryostat installation position and alignment with respect to the nominal beam position defined in the lattice file and axis shall be within the following limits:(Note: Z is along the beam axis)10/12/2026ApprovedFALSE
- 6.02.03.03.03The magnet install center displacement shall be aligned with respect to the specified lattice field center position dx=+/-100(um) dy=+/-100(um) dz= +/-710(um)10/12/2026ApprovedFALSE
- 6.02.03.03.03The magnet rotational alignment shall be aligned with respect to the specified lattice beam axis About X=+/-0.15(mrad) About Y=+/-0.15(mrad) About Z=+/-0.15(mrad)10/12/2026ApprovedFALSE
- 6.02.03.03.03This is an existing ATR magnet the magnet bore field should have the same multipole content as per the existing combined function ATR magnets. If the magnet needs to be repositioned it shall be confirmed the field quality of the bore remains unchanged.10/12/2026ApprovedFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.03The magnet cooling system shall be capable of maintaning an operational temperature range of +25 (C) to +35 (C).10/12/2026ApprovedFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.03The magnet coils shall pass a Hi-Pot test at 1(kV) at 10(uA).10/12/2026ApprovedFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.0310/12/2026Not ApplicableFALSE
- 6.02.03.03.03The magnet shall be able to sustain 30 years of EIC operation under nominal conditions.During this time the magnet is expected to survive 30000 power cycles.10/12/2026ApprovedFALSE
- 6.02.03.03.03Over its planned life of 30(yrs), the magnet Shall be able to survive a total integrated absorbed radiation dose from 1(MGy) to 20(MGy) without damage.The upper limit should be taken as a guide for the design process. The actual upper limit the magnet will see in operation will need further analysis and will need to be confirmed by the EIC radiation physics team10/12/2026ApprovedFALSE
HIN-MAG-Q:50 : HSR Injector Magnet Q2 (WBS 6.02.03.03.04)
- The magnet shall use am existing refurbished APS Q50 quadrupole magnet to provide a single function normal quadrupole field centered on the injected beam axis.10/12/2026ApprovedFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- The magnet shall be able to fit within the following volume constraints:10/12/2026ApprovedFALSE
- The magnet volume occupied shall be approved by the EIC engineering team to ensure the design does not impede any other EIC components or block egress.10/12/2026ApprovedFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- The magnet cryostat installation position and alignment with respect to the nominal beam position defined in the lattice file and axis shall be within the following limits:(Note: Z is along the beam axis)10/12/2026ApprovedFALSE
- The magnet install center displacement shall be aligned with respect to the specified lattice field center position dx=+/-100(um) dy=+/-100(um) dz= +/-710(um)10/12/2026ApprovedFALSE
- The magnet rotational alignment shall be aligned with respect to the specified lattice beam axis About X=+/-0.15(mRad) About Y=+/-0.15(mRad) About Z=+/-0.15(mRad)10/12/2026ApprovedFALSE
- This is an existing magnet the magnet bore field should have the same multipole content as per the existing combined function APS magnets.10/12/2026ApprovedFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
HIN-MAG-Q:60 : HIN Quadrupole Magnet (Q:60) (WBS 6.02.03.03.04)
- The magnet shall use am existing refurbished APS Q60 quadrupole magnet to provide a single function normal quadrupole field centered on the injected beam axis.10/12/2026ApprovedFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- The magnet shall be able to fit within the following volume constraints:10/12/2026ApprovedFALSE
- The magnet volume occupied shall be approved by the EIC engineering team to ensure the design does not impede any other EIC components or block egress.10/12/2026ApprovedFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- The magnet cryostat installation position and alignment with respect to the nominal beam position defined in the lattice file and axis shall be within the following limits:(Note: Z is along the beam axis)10/12/2026ApprovedFALSE
- The magnet install center displacement shall be aligned with respect to the specified lattice field center position dx=+/-100(um) dy=+/-100(um) dz= +/-710(um)10/12/2026ApprovedFALSE
- The magnet rotational alignment shall be aligned with respect to the specified lattice beam axis About X=+/-0.15(mRad) About Y=+/-0.15(mRad) About Z=+/-0.15(mRad)10/12/2026ApprovedFALSE
- This is an existing magnet the magnet bore field should have the same multipole content as per the existing combined function APS magnets.10/12/2026ApprovedFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
HIN-MAG-Q:80 : HIN Quadrupole Magnet (Q:80) (WBS 6.02.03.03.04)
- The magnet shall use am existing refurbished APS Q80 quadrupole magnet to provide a single function normal quadrupole field centered on the injected beam axis.10/12/2026ApprovedFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- The magnet shall be able to fit within the following volume constraints:10/12/2026ApprovedFALSE
- The magnet volume occupied shall be approved by the EIC engineering team to ensure the design does not impede any other EIC components or block egress.10/12/2026ApprovedFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- The magnet cryostat installation position and alignment with respect to the nominal beam position defined in the lattice file and axis shall be within the following limits:(Note: Z is along the beam axis)10/12/2026ApprovedFALSE
- The magnet install center displacement shall be aligned with respect to the specified lattice field center position dx=+/-100(um) dy=+/-100(um) dz= +/-710(um)10/12/2026ApprovedFALSE
- The magnet rotational alignment shall be aligned with respect to the specified lattice beam axis About X=+/-0.15(mRad) About Y=+/-0.15(mRad) About Z=+/-0.15(mRad)10/12/2026ApprovedFALSE
- This is an existing magnet the magnet bore field should have the same multipole content as per the existing combined function APS magnets.10/12/2026ApprovedFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
- 10/12/2026Not ApplicableFALSE
HIN-PS : HSR Hadron Ring Injection Power Supplys (WBS 6.02.03.04)
- HIN-PS EXTERNALSRequirements who's parents are in other sub-systems.
- 6.02.03The HSR Injection System magnets shall be fed by a system of power supplies matched in voltage and maximum current to the specifications and requirements of the respective magnets10/12/2026ApprovedFALSE
HIN-PS-CHV1 : HSR Injector Power supply Vert Corr (WBS 6.02.03.04)
- A single CHV1 power supply shall be capable of powering either the Vertical plane or the Horizontal plane of the HSR INJ CHV1 corrector. (Two power supplies are required to independently power each plane).10/12/2026ApprovedFALSE
- The CHV1 power supply shall meet all requirements to deliver the magnet operational parameters defined in the technical magnet documentation. [HSR INJ Magnet String Design Configuration [EIC-SEG-RSI-196]]10/12/2026ApprovedFALSE
- The CHV1 power supply during operation shall limit the maximum voltage of the magnet-to-ground to less than 300(V).10/12/2026ApprovedFALSE
- The CHV1 power supply shall provide a DC current.10/12/2026ApprovedFALSE
- The power supply shall include the current tuning margin of 10%.10/12/2026ApprovedFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- The CHV1 power supply long-term stability (1 second to 10 hours) at maximum operating current shall be 1000(ppm).10/12/2026ApprovedFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- The CHV1 power supply shall provide a minimal current setpoint resolution of 16(Bit).10/12/2026ApprovedFALSE
- The CHV1 power supply synchronization timing of synchronization shall be 100(us).10/12/2026ApprovedFALSE
- The CHV1 power supply setpoint and all of the PS analog readbacks shall be synchronized to the line to reduce noise.10/12/2026ApprovedFALSE
- The CHV1 power supply shall limit current ripple (Pk-Pk) to 1000(ppm) of full-scale current in the 0–1 k(Hz) range.10/12/2026ApprovedFALSE
- The CHV1 power supply shall limit current ripple (Pk-Pk) to 1000(ppm) of full scale current greater than 1k(Hz).10/12/2026ApprovedFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- The CHV1 rack mounted power supply and its controls rack shall be designed to be cooled and sustained at an operational temperature range of +23.9(C) +/- 1.7(C).10/12/2026ApprovedFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
HIN-PS-CHV2 : HSR Injector Power supply Hor Corr (WBS 6.02.03.04)
- A single power CHV2 supply shall be capable of powering either the Vertical plane or the Horizontal plane of the HSR INJ CHV2 corrector. (Two power supplies are required to independently power each plane).10/12/2026ApprovedFALSE
- The CHV2 power supply shall meet all requirements to deliver the magnet operational parameters defined in the technical magnet documentation. [HSR INJ Magnet String Design Configuration [EIC-SEG-RSI-196]]10/12/2026ApprovedFALSE
- The CHV2 power supply during operation shall limit the maximum voltage of the magnet-to-ground to less than 300(V).10/12/2026ApprovedFALSE
- The CHV2 power supply shall provide a DC current.10/12/2026ApprovedFALSE
- The power supply shall include the current tuning margin of 10%.10/12/2026ApprovedFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- The CHV2 power supply long-term stability (1 second to 10 hours) at maximum operating current shall be 1000(ppm).10/12/2026ApprovedFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- The CHV2 power supply shall provide a minimal current setpoint resolution of 16(Bit).10/12/2026ApprovedFALSE
- The CHV2 power supply synchronization timing of synchronization shall be 100(us).10/12/2026ApprovedFALSE
- The CHV2 power supply setpoint and all of the PS analog readbacks shall be synchronized to the line to reduce noise.10/12/2026ApprovedFALSE
- The CHV2 power supply shall limit current ripple (Pk-Pk) to 1000(ppm) of full-scale current in the 0–1 k(Hz) range.10/12/2026ApprovedFALSE
- The CHV2 power supply shall limit current ripple (Pk-Pk) to 1000(ppm) of full scale current greater than 1k(Hz).10/12/2026ApprovedFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- The CHV2 rack mounted power supply and its controls rack shall be designed to be cooled and sustained at an operational temperature range of +23.9(C) +/- 1.7(C).10/12/2026ApprovedFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
HIN-PS-DV1 : HSR Injector Power supply D3 (WBS 6.02.03.04)
- The magnet model being powered shall be the HSR INJ MAGNET DV110/12/2026ApprovedFALSE
- The DV1 power supply shall meet all requirements to deliver the magnet operational parameters defined in the technical magnet documentation. [HSR INJ Magnet String Design Configuration [EIC-SEG-RSI-196]]10/12/2026ApprovedFALSE
- The DV1 power supply during operation shall limit the maximum voltage of the magnet-to-ground to less than 300(V).10/12/2026ApprovedFALSE
- The DV1 power supply shall provide a DC current.10/12/2026ApprovedFALSE
- The power supply shall include the current tuning margin of 10%.10/12/2026ApprovedFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- The DV1 power supply long-term stability (1 second to 10 hours) at maximum operating current shall be 200(ppm).10/12/2026ApprovedFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- The DV1 power supply shall provide a minimal current setpoint resolution of 16(Bit).10/12/2026ApprovedFALSE
- The DV1 power supply synchronization timing of 100(us).10/12/2026ApprovedFALSE
- The DV1 power supply setpoint and all the PS analog readbacks shall be synchronized to the line to reduce noise.10/12/2026ApprovedFALSE
- The DV1 power supply shall limit current ripple (Pk-Pk) to 100(ppm) of full-scale current in the 0–1 k(Hz) range.10/12/2026ApprovedFALSE
- The DV1 power supply shall limit current ripple (Pk-Pk) to 200(ppm) of full scale current greater than 1k(Hz).10/12/2026ApprovedFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- The DV1 rack mounted power supply and its controls rack shall be designed to be cooled and sustained at an operational temperature range of +23.9(C) +/- 1.7(C).10/12/2026ApprovedFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
HIN-PS-DW0 : HSR Injector Power supply D4 (WBS 6.02.03.04)
- The magnet model being powered shall be the HSR INJ MAGNET DW010/12/2026ApprovedFALSE
- The DW0 power supply shall meet all requirements to deliver the magnet operational parameters defined in the technical magnet documentation. [HSR INJ Magnet String Design Configuration [EIC-SEG-RSI-196]]10/12/2026ApprovedFALSE
- The DW0 power supply during operation shall limit the maximum voltage of the magnet-to-ground to less than 300(V).10/12/2026ApprovedFALSE
- The DW0 power supply shall provide a DC current.10/12/2026ApprovedFALSE
- The power supply shall include the current tuning margin of 10%.10/12/2026ApprovedFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- The DW0 power supply long-term stability (1 second to 10 hours) at maximum operating current shall be 200(ppm).10/12/2026ApprovedFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- The DW0 power supply shall provide a minimal current setpoint resolution of 16(Bit).10/12/2026ApprovedFALSE
- The DW0 power supply synchronization timing of synchronization shall be 100(us).10/12/2026ApprovedFALSE
- The DW0 power supply setpoint and all the PS analog readbacks shall be synchronized to the line to reduce noise.10/12/2026ApprovedFALSE
- The DW0 power supply shall limit current ripple (Pk-Pk) to 100(ppm) of full-scale current in the 0–1 k(Hz) range.10/12/2026ApprovedFALSE
- The DW0 power supply shall limit current ripple (Pk-Pk) to 200(ppm) of full scale current greater than 1k(Hz).10/12/2026ApprovedFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- The DW0 rack mounted power supply and its controls rack shall be designed to be cooled and sustained at an operational temperature range of +23.9(C) +/- 1.7(C).10/12/2026ApprovedFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
HIN-PS-Q:100 : HIN Quadrupole Magnet (Q:100) Power Supply (WBS 6.02.03.04)
- The magnet model being powered shall be the HSR INJ MAGNET Q:10010/12/2026ApprovedFALSE
- The Q:100 power supply shall meet all requirements to deliver the magnet operational parameters defined in the technical magnet documentation. [HSR INJ Magnet String Design Configuration [EIC-SEG-RSI-196]]10/12/2026ApprovedFALSE
- The Q:100 power supply during operation shall limit the maximum voltage of the magnet-to-ground to less than 300(V).10/12/2026ApprovedFALSE
- The Q:100 power supply shall provide a DC current.10/12/2026ApprovedFALSE
- The power supply shall include the current tuning margin of 10%.10/12/2026ApprovedFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- The Q:100 power supply long-term stability (1 second to 10 hours) at maximum operating current shall be 200(ppm).10/12/2026ApprovedFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- The Q:100 power supply shall provide a minimal current setpoint resolution of 16(Bit).10/12/2026ApprovedFALSE
- The Q:100 power supply synchronization timing of synchronization shall be 100(us).10/12/2026ApprovedFALSE
- The Q:100 power supply setpoint and all of the PS analog readbacks shall be synchronized to the line to reduce noise.10/12/2026ApprovedFALSE
- The Q:100 power supply shall limit current ripple (Pk-Pk) to 100(ppm) of full-scale current in the 0–1 k(Hz) range.10/12/2026ApprovedFALSE
- The Q:100 power supply shall limit current ripple (Pk-Pk) to 200(ppm) of full scale current greater than 1k(Hz).10/12/2026ApprovedFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- The Q:100 rack mounted power supply and its controls rack shall be designed to be cooled and sustained at an operational temperature range of +23.9(C) +/- 1.7(C).10/12/2026ApprovedFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
HIN-PS-Q:50 : HSR Injector Power supply Q1 (WBS 6.02.03.04)
- The magnet model being powered shall be the HSR INJ MAGNET Q:5010/12/2026ApprovedFALSE
- The Q:50 power supply shall meet all requirements to deliver the magnet operational parameters defined in the technical magnet documentation. [HSR INJ Magnet String Design Configuration [EIC-SEG-RSI-196]]10/12/2026ApprovedFALSE
- The Q:50 power supply during operation shall limit the maximum voltage of the magnet-to-ground to less than 300(V).10/12/2026ApprovedFALSE
- The Q:50 power supply shall provide an DC current.10/12/2026ApprovedFALSE
- The power supply shall include the current tuning margin of 10%.10/12/2026ApprovedFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- The Q:50 power supply long-term stability (1 second to 10 hours) at maximum operating current shall be 200(ppm).10/12/2026ApprovedFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- The Q:50 power supply shall provide a minimal current setpoint resolution of 16(Bit).10/12/2026ApprovedFALSE
- The Q:50 power supply synchronization timing of synchronization shall be 100(us).10/12/2026ApprovedFALSE
- The Q:50 power supply setpoint and all the PS analog readbacks shall be synchronized to the line to reduce noise.10/12/2026ApprovedFALSE
- The Q:50 power supply shall limit current ripple (Pk-Pk) to 100(ppm) of full-scale current in the 0–1 k(Hz) range.10/12/2026ApprovedFALSE
- The Q:50 power supply shall limit current ripple (Pk-Pk) to 200(ppm) of full scale current greater than 1k(Hz).10/12/2026ApprovedFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- The Q:50 rack mounted power supply and its controls rack shall be designed to be cooled and sustained at an operational temperature range of +23.9(C) +/- 1.7(C).10/12/2026ApprovedFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
HIN-PS-Q:60 : HSR Injector Power supply Q2 (WBS 6.02.03.04)
- The magnet model being powered shall be the HSR INJ MAGNET Q:6010/12/2026ApprovedFALSE
- The Q:60 power supply shall meet all requirements to deliver the magnet operational parameters defined in the technical magnet documentation. [HSR INJ Magnet String Design Configuration [EIC-SEG-RSI-196]]10/12/2026ApprovedFALSE
- The Q:60 power supply during operation shall limit the maximum voltage of the magnet-to-ground to less than 300(V).10/12/2026ApprovedFALSE
- The Q:60 power supply shall provide a DC current.10/12/2026ApprovedFALSE
- The power supply shall include the current tuning margin of 10%.10/12/2026ApprovedFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- The Q:60 power supply long-term stability (1 second to 10 hours) at maximum operating current shall be 200(ppm).10/12/2026ApprovedFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- The Q:60 power supply shall provide a minimal current setpoint resolution of 16(Bit).10/12/2026ApprovedFALSE
- The Q:60 power supply synchronization timing of synchronization shall be 100(us).10/12/2026ApprovedFALSE
- The Q:60 power supply setpoint and all the PS analog readbacks shall be synchronized to the line to reduce noise.10/12/2026ApprovedFALSE
- The Q:60 power supply shall limit current ripple (Pk-Pk) to 100(ppm) of full-scale current in the 0–1 k(Hz) range.10/12/2026ApprovedFALSE
- The Q:60 power supply shall limit current ripple (Pk-Pk) to 200(ppm) of full scale current greater than 1k(Hz).10/12/2026ApprovedFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- The Q:60 rack mounted power supply and its controls rack shall be designed to be cooled and sustained at an operational temperature range of +23.9(C) +/- 1.7(C).10/12/2026ApprovedFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
HIN-PS-Q:80 : HSR Injector Power supply Q3 (WBS 6.02.03.04)
- The magnet model being powered shall be the HSR INJ MAGNET Q:8010/12/2026ApprovedFALSE
- The Q:80 power supply shall meet all requirements to deliver the magnet operational parameters defined in the technical magnet documentation. [HSR INJ Magnet String Design Configuration [EIC-SEG-RSI-196]]10/12/2026ApprovedFALSE
- The Q:80 power supply during operation shall limit the maximum voltage of the magnet-to-ground to less than 300(V).10/12/2026ApprovedFALSE
- The Q:80 power supply shall provide a DC current.10/12/2026ApprovedFALSE
- The power supply shall include the current tuning margin of 10%.10/12/2026ApprovedFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- The Q:80 power supply long-term stability (1 second to 10 hours) at maximum operating current shall be 200(ppm).10/12/2026ApprovedFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- The Q:80 power supply shall provide a minimal current setpoint resolution of 16(Bit).10/12/2026ApprovedFALSE
- The Q:80 power supply synchronization timing of synchronization shall be 100(us).10/12/2026ApprovedFALSE
- The Q:80 power supply setpoint and all of the PS analog readbacks shall be synchronized to the line to reduce noise.10/12/2026ApprovedFALSE
- The Q:80 power supply shall limit current ripple (Pk-Pk) to 100(ppm) of full-scale current in the 0–1 k(Hz) range.10/12/2026ApprovedFALSE
- The Q:80 power supply shall limit current ripple (Pk-Pk) to 200(ppm) of full scale current greater than 1k(Hz).10/12/2026ApprovedFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- The Q:80 rack mounted power supply and its controls rack shall be designed to be cooled and sustained at an operational temperature range of +23.9(C) +/- 1.7(C).10/12/2026ApprovedFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
HIN-PS-QD1 : HSR Injector Power supply QD1 (WBS 6.02.03.04)
- The magnet model being powered shall be the HSR INJ MAGNET QD110/12/2026ApprovedFALSE
- The QD1 power supply shall meet all requirements to deliver the magnet operational parameters defined in the technical magnet documentation. [HSR INJ Magnet String Design Configuration [EIC-SEG-RSI-196]]10/12/2026ApprovedFALSE
- The QD1 power supply during operation shall limit the maximum voltage of the magnet-to-ground to less than 300 (V).10/12/2026ApprovedFALSE
- The QD1 power supply shall provide DC current .10/12/2026ApprovedFALSE
- The power supply shall supply the nominal current required by HSR INJ Magnet String Design Configuration [EIC-SEG-RSI-196] .10/12/2026ApprovedFALSE
- The power supply shall supply the nominal current required with an additional current tuning margin of 10%.10/12/2026ApprovedFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- The QD1 power supply long-term stability (1 second to 10 hours) at maximum operating current shall be 200(ppm).10/12/2026ApprovedFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- The QD1 power supply shall provide a minimal current setpoint resolution of 16(Bit).10/12/2026ApprovedFALSE
- The QD1 power supply synchronization timing shall be 100(us).10/12/2026ApprovedFALSE
- The QD1 power supply setpoint and all the PS analog readbacks shall be synchronized to the line to reduce noise.10/12/2026ApprovedFALSE
- The QD1 power supply shall limit current ripple (Pk-Pk) to 100(ppm) of full-scale current in the 0–1 k(Hz) range.10/12/2026ApprovedFALSE
- The QD1 power supply shall limit current ripple (Pk-Pk) to 200(ppm) of full scale current greater than 1k(Hz).10/12/2026ApprovedFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- The QD1 rack mounted power supply and its controls rack shall be designed to be cooled and sustained at an operational temperature range of +23.9(C) +/- 1.7(C).10/12/2026ApprovedFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
HIN-PS-QD2 : HIN Quadrupole Magnet (QD2) Power Supply (WBS 6.02.03.04)
- The magnet model being powered shall be the HSR INJ MAGNET QD210/12/2026ApprovedFALSE
- The QD2 power supply shall meet all requirements to deliver the magnet operational parameters defined in the technical magnet documentation. [HSR INJ Magnet String Design Configuration [EIC-SEG-RSI-196]]10/12/2026ApprovedFALSE
- The QD2 power supply during operation shall limit the maximum voltage of the magnet-to-ground to less than 300(V).10/12/2026ApprovedFALSE
- The QD2 power supply shall provide a DC current.10/12/2026ApprovedFALSE
- The power supply shall include the current tuning margin of 10%.10/12/2026ApprovedFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- The QD2 power supply long-term stability (1 second to 10 hours) at maximum operating current shall be 200(ppm).10/12/2026ApprovedFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- The QD2 power supply shall provide a minimal current setpoint resolution of 16(Bit).10/12/2026ApprovedFALSE
- The QD2 power supply synchronization timing of 100(us).10/12/2026ApprovedFALSE
- The QD2 power supply setpoint and all of the PS analog readbacks shall be synchronized to the line to reduce noise.10/12/2026ApprovedFALSE
- The QD2 power supply shall limit current ripple (Pk-Pk) to 100(ppm) of full-scale current in the 0–1 k(Hz) range.10/12/2026ApprovedFALSE
- The QD2 power supply shall limit current ripple (Pk-Pk) to 200(ppm) of full scale current greater than 1k(Hz).10/12/2026ApprovedFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- The QD2 rack mounted power supply and its controls rack shall be designed to be cooled and sustained at an operational temperature range of +23.9(C) +/- 1.7(C).10/12/2026ApprovedFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
HIN-PS-QLA:100 : HIN Large Aperture Quadrupole Magnet (QLA:100) Power Supply (WBS 6.02.03.04)
- The magnet model being powered shall be the HSR INJ MAGNET QLA:10010/12/2026ApprovedFALSE
- The QLA:100 power supply shall meet all requirements to deliver the magnet operational parameters defined in the technical magnet documentation. [HSR INJ Magnet String Design Configuration [EIC-SEG-RSI-196]]10/12/2026ApprovedFALSE
- The QLA:100 power supply during operation shall limit the maximum voltage of the magnet-to-ground to less than 300(V).10/12/2026ApprovedFALSE
- The QLA:100 power supply shall provide a DC current.10/12/2026ApprovedFALSE
- The power supply shall include the current tuning margin of 10%.10/12/2026ApprovedFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- The QLA:100 power supply long-term stability (1 second to 10 hours) at maximum operating current shall be 200(ppm).10/12/2026ApprovedFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- The QLA:100 power supply shall provide a minimal current setpoint resolution of 16(Bit).10/12/2026ApprovedFALSE
- The QLA:100 power supply synchronization timing of synchronization shall be 100(us).10/12/2026ApprovedFALSE
- The QLA:100 power supply setpoint and all of the PS analog readbacks shall be synchronized to the line to reduce noise.10/12/2026ApprovedFALSE
- The QLA:100 power supply shall limit current ripple (Pk-Pk) to 100(ppm) of full-scale current in the 0–1 k(Hz) range.10/12/2026ApprovedFALSE
- The QLA:100 power supply shall limit current ripple (Pk-Pk) to 200(ppm) of full scale current greater than 1k(Hz).10/12/2026ApprovedFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- The QLA:100 rack mounted power supply and its controls rack shall be designed to be cooled and sustained at an operational temperature range of +23.9(C) +/- 1.7(C).10/12/2026ApprovedFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
HIN-PS-YQ1 : HIN Quadrupole Magnet (YQ1) Power Supply (WBS 6.02.03.04)
- The magnet model being powered shall be the HSR INJ MAGNET YQ110/12/2026ApprovedFALSE
- The YQ1 power supply shall meet all requirements to deliver the magnet operational parameters defined in the technical magnet documentation. [HSR INJ Magnet String Design Configuration [EIC-SEG-RSI-196]]10/12/2026ApprovedFALSE
- The YQ1 power supply during operation shall limit the maximum voltage of the magnet-to-ground to less than 300(V).10/12/2026ApprovedFALSE
- The YQ1 power supply shall provide a DC current.10/12/2026ApprovedFALSE
- The power supply shall include the current tuning margin of 10%.10/12/2026ApprovedFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- The YQ1 power supply long-term stability (1 second to 10 hours) at maximum operating current shall be 200(ppm).10/12/2026ApprovedFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- The YQ1 power supply shall provide a minimal current setpoint resolution of 16(Bit).10/12/2026ApprovedFALSE
- The YQ1 power supply synchronization timing of synchronization shall be 100(us).10/12/2026ApprovedFALSE
- The YQ1 power supply setpoint and all the PS analog readbacks shall be synchronized to the line to reduce noise.10/12/2026ApprovedFALSE
- The YQ1 power supply shall limit current ripple (Pk-Pk) to 100(ppm) of full-scale current in the 0–1 k(Hz) range.10/12/2026ApprovedFALSE
- The YQ1 power supply shall limit current ripple (Pk-Pk) to 200(ppm) of full scale current greater than 1k(Hz).10/12/2026ApprovedFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- The YQ1 rack mounted power supply and its controls rack shall be designed to be cooled and sustained at an operational temperature range of +23.9(C) +/- 1.7(C).10/12/2026ApprovedFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
- < Requirement Not Applicable >10/12/2026Not ApplicableFALSE
HIN-INST : HSR Hadron Ring Injection Instrumentation System (WBS 6.02.03.05.07)
- 6.02.03The HSR injection line shall have Beam instrumentation to monitor the following beam parameters: beam orbit, beam current, beam transverse sizes, beam loss rate.10/12/2026ApprovedFALSE
- 6.02.03Beam instrumentation shall be capable of providing operational data in the injection configuration for all the species and energies given in MPT. [Document: EIC-SEG-RSI-005]10/12/2026ApprovedFALSE
- 6.02.03The new warm transfer line from the RHIC-ATR to the HSR shall re-use existing BPMs with the same requirements as the existing RHIC-ATR BPMs.10/12/2026ApprovedFALSE
- 6.02.03The new warm transfer line from the RHIC-ATR to the HSR shall use HSR BPM electronics for the Injection line BPMs.10/12/2026ApprovedFALSE
- 6.02.03The new warm transfer line from the RHIC-ATR to the HSR shall re-use the existing Phosphor screen beam profile monitors with the same requirements as existing in the RHIC-ATR Phosphor screen beam profile monitors.10/12/2026ApprovedFALSE
- 6.02.03The new warm transfer line from the RHIC-ATR to the HSR shall re-use the existing Current transformers with the same requirements as existing in the RHIC-ATR Current transformers.10/12/2026ApprovedFALSE
- 6.02.03The new warm transfer line from the RHIC-ATR to the HSR shall re-use the existing Beam loss monitors with the same requirements as existing in the RHIC-ATR Beam loss monitors.10/12/2026ApprovedFALSE
- 6.02.04.02The new warm transfer line from the RHIC-ATR to the HSR shall have strategically placed chipmunks for radiation control.10/12/2026ApprovedFALSE
HIN-INST-BC : HSR ATR Instrumentation Beam Charge Monitor (WBS 6.05.05.02)
- 6.02.03.05.07The HSR Injection beamline bunch charge monitors shall measure single bunches over the measurement range up to 44 (nC).10/12/2026ApprovedFALSE
- 6.02.03.05.07The HSR Injection beamline bunch charge monitors shall have a measurement resolution of at least 100 (pC).10/12/2026ApprovedFALSE
- 6.02.03.05.07The HSR Injection beamline bunch charge monitor shall be capable of charge measurements for bunch lengths between 40 to 150 (cm) (rms).10/12/2026ApprovedFALSE
- 6.02.03.05.07The HSR Injection beamline bunch charge monitor measurement shall vary less than +/- 0.1 (%) per mm of beam offset within half of the beamline aperture for charges greater than 5 (nC).10/12/2026ApprovedFALSE
- 6.02.03.05.07The HSR Injection beamline bunch charge monitor system measurement accuracy shall vary less than +/- 5 (%) shot to shot for bunches greater than 5 (nC).10/12/2026ApprovedFALSE
- 6.02.03.05.07The HSR Injection beamline bunch charge monitor sensor shall operate in ultra-high vacuum.10/12/2026ApprovedFALSE
- 6.02.03.05.07The HSR Injection beamline bunch charge monitor system shall have a remote controlled self calibration system.10/12/2026ApprovedFALSE
- 6.02.03.05.07The HSR Injection beamline bunch charge monitor calibration system shall be capable of providing pulses with a defined charge value that has greater than +/- 2 (%) accuracy.10/12/2026ApprovedFALSE
- 6.02.03.05.07The HSR Injection beamline bunch charge monitor shall provide bunch charge measurements at a rate less than 5 (Hz).10/12/2026ApprovedFALSE
- 6.02.03.05.07The HSR Injection beamline bunch charge monitor shall be a radiation hardened device.10/12/2026ApprovedFALSE
HIN-INST-BC-CM : HIN INST BC Charge Monitor
HIN-INST-BC-ELEC : HIN INST BC Electrical Systems
HIN-INST-BLM : HSR ATR Instrumentation Beam Loss Monitors (WBS 6.05.05.02)
- 6.02.03.05.07The ATR BLM''s shall be the same as the RHIC type BLM''s or an equavilent model having at least the same functionality tbd10/12/2026In ProcessFALSE
- 6.02.03.05.07The ATR shall have BLM''s at the following locations tbd10/12/2026In ProcessFALSE
HIN-INST-BLM-ELEC : HIN INST Beam Loss Monitor Electronics
HIN-INST-BLM-PU : HIN INST Beam Loss Monitor Pickup
HIN-INST-BPM : HSR ATR Instrumentation Beam Position Monitor (WBS 6.05.05.02)
- 6.02.03.05.07The ATR BPM''s shal have a (single pass) position measurement resolution of 100 µm10/12/2026In ProcessFALSE
- 6.02.03.05.07The existing RHIC stripline BPMs in the blue arc cryostat between sector 6 to 4 shall be re-used, but new modern electronics shall be added.10/12/2026In ProcessFALSE
- 6.02.03.05.07The following locations on the ATR transfer line shall have BPM tbd10/12/2026In ProcessFALSE
- 6.02.03.05.07The beam pipe aperture for the warm HT BPMs shall be 5 cm10/12/2026In ProcessFALSE
HIN-INST-BPM-ELEC : HIN INST Beam Position Monitor Electronics
HIN-INST-BPM-PU : HIN INST Beam Position Monitor Pickup
HIN-INST-PM : HSR ATR Instrumentation Profile Monitor (WBS 6.05.05.02)
- 6.02.03.05.07The ATR PM''s posphour screens shall have a Transverse optical resolution of 100 µm10/12/2026In ProcessFALSE
- 6.02.03.05.07The ATR shall have Transverse PM Posphour screens in the following locations tbd10/12/2026In ProcessFALSE
- 6.02.03.05.07The beam pipe aperture for the warm HT transverse profile monitors shall be 5 cm10/12/2026In ProcessFALSE
HIN-INST-PM-CM : HIN INST Profile Monitor Charge Monitor
HIN-INST-PM-ELEC : HIN INST Profile Monitor Electronics
HIN-VAC : HSR Hadron Ring Injection Vacuum System (WBS 6.02.03.06.06)
- 6.02.03.06.06The average vacuum level in the transfer line from the AGS to the HSR after conditioning (for 6mts) shall be <<1x10-8 Torr10/12/2026ApprovedFALSE
- 6.02.03.06.06The vacuum stability (upper pressure limit excursions) shall be less than TBD.10/12/2026In ProcessFALSE
- HIN-VAC EXTERNALSRequirements who's parents are in other sub-systems.
- 6.02.03The vacuum level in the HSR transport line shall be kept at the same level as in the current RHIC-ATR line.10/12/2026ApprovedFALSE
- 6.02.03A ~20m section of the warm injection beamline near the HSR including the injection septum shall have a vacuum pressure of ~1E-10 torr or better, after baking .10/12/2026ApprovedFALSE
HIN-PPD : HSR Hadron Ring Injection Pulsed Power Devices System (WBS 6.02.03.11.01)
- HIN-PPD EXTERNALSRequirements who's parents are in other sub-systems.
- 6.02.03The HSR injection kickers shall provide a half aperture greater than 10σ for the stored beam at Collison energies.10/12/2026ApprovedFALSE
- 6.02.03The HSR injection kickers shall provide a half aperture greater than 7σ for the stored beam at injection energies.10/12/2026ApprovedFALSE
- 6.02.03The HSR injection kickers shall provide a half aperture greater than 6σ for the injected beam.10/12/2026ApprovedFALSE
- 6.02.03The HSR injection kicker system shall be able to deflect the injected beam to be on axis10/12/2026ApprovedFALSE
- 6.02.03The HSR injection kicker system shall be installed in the straight section of the IR4 area.10/12/2026ApprovedFALSE
- 6.02.03The HSR injection kicker system shall be capable of single-bunch on-axis injection to fill the ring with 290 bunches.10/12/2026ApprovedFALSE
- 6.02.03The HSR injection kicker system rise time shall be short enough so that it does not step on the previous bunch.10/12/2026ApprovedFALSE
- 6.02.03The present RHIC injection kicker system including the Lambertson magnet and current injection kicker magnets at the 5 o’clock area shall be removed.10/12/2026ApprovedFALSE
HIN-PPD-MAG : HIN PPD Magnet Systems
HIN-PPD-MAG-DCSPTM : HIN PPD DC Septum Magnet
- 6.02.03.11.03The magnet shall be a single function DC septum with vertical dipole field.10/12/2026ApprovedFALSE
- 6.02.03.11.03The DC septum physical magnet length shall be 2.5 m.10/12/2026ApprovedFALSE
- 6.02.03.11.03The DC septum thickness shall be less than or equal to 21.2 (mm), inclusive of beampipe wall thicknesses, and be able to accommodate the transfer line beampipe.10/12/2026ApprovedFALSE
- 6.02.03.11.03The DC septum shall be designed to fit within the following constraints:10/12/2026ApprovedFALSE
- 6.02.03.11.03The DC septum shall fit within an envelope of L=3.1 (m) x W=0.6 (m) x H=1.8 (m).10/12/2026ApprovedFALSE
- 6.02.03.11.03The DC septum pole gap height and width shall be H=27.432 (mm), W=128.803 (mm).10/12/2026ApprovedFALSE
- 6.02.03.11.03The DC septum final magnet assembly position and alignment values with respect to the nominal beam position and axis shall be within the following limits: (Note: Z is along the beam axis)10/12/2026ApprovedFALSE
- 6.02.03.11.03The DC septum install center displacement (measured with respect to the nominal magnet center position) shall be dX=±150 (µm), dY=±150 (µm), dZ= ±150 (µm).10/12/2026ApprovedFALSE
- 6.02.03.11.03The DC septum install rotational alignment (measured with respect to the nominal beam axis) shall be X= ±0.1 (mrad)), Y=±0.1 (mrad), Z=±0.2 (mrad).10/12/2026ApprovedFALSE
- 6.02.03.11.03The DC septum integrated dipole field shall provide a deflection angle of at least ~27 (mrad) with a peak field in the magnet held below 1 (T).10/12/2026ApprovedFALSE
- 6.02.03.11.03The DC septum field alignment within the magnet, position and alignment values shall be within the following tolerance limits: (Note: Z is along the beam axis)10/12/2026ApprovedFALSE
- 6.02.03.11.03The DC septum field center displacement (measured with respect to the physical magnet center) shall be X= ±50 (µm), Y= ±50 (µm), Z= ±50 (µm)10/12/2026ApprovedFALSE
- 6.02.03.11.03The DC septum field rotational alignment (measured with respect to the physical magnet’s primary axis X, Y, Z) shall be X=±0.1(mrad), Y=±0.1(mrad), Z=±0.2(mrad)10/12/2026ApprovedFALSE
- 6.02.03.11.03The DC septum shall be designed to meet the following field quality\multipole requirements.10/12/2026ApprovedFALSE
- 6.02.03.11.03The DC septum harmonic reference radius at which the field quality shall be measured is 25 (mm).10/12/2026ApprovedFALSE
- 6.02.03.11.03The DC septum field (Bref) or design energy or beam rigidity for which the field quality shall be measured are 52.03 (Tm) and 81.12 (Tm).10/12/2026ApprovedFALSE
- 6.02.03.11.03The DC septum shall have the following Multipole content or dB/B within the specified measurement volumes:10/12/2026ApprovedFALSE
- 6.02.03.11.03b1 = 10000, a1 ≤ ±1010/12/2026ApprovedFALSE
- 6.02.03.11.03b2 < ±10, a2 ≤ ±1010/12/2026ApprovedFALSE
- 6.02.03.11.03b3 < ±10, a3 ≤ ±1010/12/2026ApprovedFALSE
- 6.02.03.11.03b4 < ±10, a4 ≤ ±1010/12/2026ApprovedFALSE
- 6.02.03.11.03b5 < ±10, a5 ≤ ±1010/12/2026ApprovedFALSE
- 6.02.03.11.03b6 < ±10, a6 ≤ ±1010/12/2026ApprovedFALSE
- 6.02.03.11.03b7 < ±10, a7 ≤ ±1010/12/2026ApprovedFALSE
- 6.02.03.11.03b8 < ±10, a8 ≤ ±1010/12/2026ApprovedFALSE
- 6.02.03.11.03b9 < ±10, a9 ≤ ±1010/12/2026ApprovedFALSE
- 6.02.03.11.03b10 <±10, a10 ≤ ±1010/12/2026ApprovedFALSE
- 6.02.03.11.03b11 < ±10, a11 ≤ ±1010/12/2026ApprovedFALSE
- 6.02.03.11.03b12 < ±10, a12 ≤ ±1010/12/2026ApprovedFALSE
- 6.02.03.11.03b13 < ±10, a13 ≤ ±1010/12/2026ApprovedFALSE
- 6.02.03.11.03b14 < ±10, a14 ≤ ±1010/12/2026ApprovedFALSE
- 6.02.03.11.03b15 < ±10, a15 ≤ ±1010/12/2026ApprovedFALSE
- 6.02.03.11.03b16 < ±10, a16 ≤ ±1010/12/2026ApprovedFALSE
- 6.02.03.11.03The DC septum fringe field shall not exceed 10 Gauss on the path of the circulating beam in HSR.10/12/2026ApprovedFALSE
- 6.02.03.11.03The DC septum field shall have a field homogeneity of better than 1x10-3.10/12/2026ApprovedFALSE
- 6.02.03.11.03The magnet-cross-talk from the DC septum on the HSR circulating beam shall be less than 1x10-3, with respect to the main field on injected beam.10/12/2026ApprovedFALSE
- 6.02.03.11.03The DC septum shall be designed with components capable of withstanding a radiation dose of 1 (MGy)10/12/2026ApprovedFALSE
- 6.02.03.11.03The DC septum design and verification process shall ensure the final magnet will meet the reliability needs of the EIC over its planned operational life of >30 years.10/12/2026ApprovedFALSE
HIN-PPD-MAG-HSLK : HIN PPD Stripline Kicker Magnet
- 6.02.03.11.01The magnets shall be horizontal stripline kickers.10/12/2026ApprovedFALSE
- 6.02.03.11.01The stripline kicker location shall be in the HSR IR4 straight section.10/12/2026ApprovedFALSE
- 6.02.03.11.01The stripline kicker shall fit within a slot length of 21.5 (m), which includes the bellows length.10/12/2026ApprovedFALSE
- 6.02.03.11.01The stripline kicker shall fit within an overall slot height and width that prevents interference with the ESR beamline.10/12/2026ApprovedFALSE
- 6.02.03.11.01The stripline kicker install center and install alignment must be within a translational value of ±100 (µm) and a rotational alignment value of ±0.2 (mrad).10/12/2026ApprovedFALSE
- 6.02.03.11.01The stripline kicker shall maintain a minimum horizontal full aperture of 59 (mm).10/12/2026ApprovedFALSE
- 6.02.03.11.01The total deflecting angle for the sum of all stripline kickers shall be 0.7 (mrad).10/12/2026ApprovedFALSE
- 6.02.03.11.01The stripline kicker characteristic impedance shall be 50 (Ω).10/12/2026ApprovedFALSE
- 6.02.03.11.01The maximum stripline kicker voltage shall be ±22,000 (V), 44,000 (V) across both kickers.10/12/2026ApprovedFALSE
- 6.02.03.11.01The field variation between stripline kicker modules shall be less than 1 (%).10/12/2026ApprovedFALSE
- 6.02.03.11.01The stripline kicker electric field shall have a field homogeneity of better than 5E-3 across X and Y dimensions in the center of the kicker.10/12/2026ApprovedFALSE
- 6.02.03.11.01The stripline kicker voltage rise time (2–98 % of full-scale amplitude) shall be < 9 (ns).10/12/2026ApprovedFALSE
- 6.02.03.11.01The stripline kicker voltage fall time (98–2 % of full-scale amplitude) shall be < 1 (us).10/12/2026ApprovedFALSE
- 6.02.03.11.01The stripline kicker flat top time shall be longer than 35 (ns).10/12/2026ApprovedFALSE
- 6.02.03.11.01The stripline kicker flat top repeatability shall be ±1 (%).10/12/2026ApprovedFALSE
- 6.02.03.11.01The uniformity of the stripline kicker flattop shall be ±1 (%).10/12/2026ApprovedFALSE
- 6.02.03.11.01The stripline kicker burst mode shall support a repetition rate of 4 pulses separated by 100 (ms) repeated every AGS cycle.10/12/2026ApprovedFALSE
- 6.02.03.11.01The stripline kicker jitter of the rise time between the positive and negative voltage shall be less than ±0.5 (ns).10/12/2026ApprovedFALSE
- 6.02.03.11.01The stripline kicker jitter of the rise time between all kicker modules shall be less than ±0.5 (ns).10/12/2026ApprovedFALSE
- 6.02.03.11.01The stripline kicker electrodes shall be electrically conductive to meet the required coupling impedance.10/12/2026ApprovedFALSE
- 6.02.03.11.01The stripline kicker electrode shall be coated with a material appropriate to minimize electron cloud effects.10/12/2026ApprovedFALSE
- 6.02.03.11.01The stripline kicker shall be designed with components capable of withstanding a radiation dose of 1 (MGy).10/12/2026ApprovedFALSE
- 6.02.03.11.01The stripline kicker design and verification process shall ensure the final magnet will meet the reliability needs of the EIC over its planned operational life of >30 years.10/12/2026ApprovedFALSE
HIN-PPD-MAG-INDSPTM : HIN PPD Induction Septum Magnet
- 6.02.03.11.02.01.01The magnet shall be a single function induction septum with vertical dipole field.10/12/2026ApprovedFALSE
- 6.02.03.11.02.01.01The induction septum physical magnet length shall be 1.3 (m).10/12/2026ApprovedFALSE
- 6.02.03.11.02.01.01The induction septum thickness shall be less than or equal to 4 (mm), inclusive of beampipe wall thicknesses, and be able to accommodate the transfer line beampipe.10/12/2026ApprovedFALSE
- 6.02.03.11.02.01.01The induction septum shall be designed to fit within the following constraints:10/12/2026ApprovedFALSE
- 6.02.03.11.02.01.01The induction septum pole gap height and width shall be H=TBD (mm), W= TBD (mm)10/12/2026ReviewedFALSE
- 6.02.03.11.02.01.01The induction septum circulating beampipe shall be circular with an aperture of ~67 (mm).10/12/2026ApprovedFALSE
- 6.02.03.11.02.01.01The induction septum final magnet assembly position and alignment values with respect to the nominal beam position and axis shall be within the following limits: (Note: Z is along the beam axis)10/12/2026ApprovedFALSE
- 6.02.03.11.02.01.01The induction septum install center displacement (measured with respect to the nominal magnet center position) shall be dX=±150 (µm), dY=±150 (µm), dZ= ±150 (µm).10/12/2026ApprovedFALSE
- 6.02.03.11.02.01.01The induction septum install rotational alignment (measured with respect to the nominal beam axis) shall be X=±0.1 (mrad), Y=±0.1 (mrad), Z=±0.2 (mrad).10/12/2026ApprovedFALSE
- 6.02.03.11.02.01.01The induction septum integrated dipole field (B) shall provide a deflection angle of ~15 (mrad) (B ~0.936 T). With a peak field in the magnet held below 1 (T).10/12/2026ApprovedFALSE
- 6.02.03.11.02.01.01The induction septum ramp rate shall be able to accommodate four (4) bunches per AGS cycle separated by 100 (ms).10/12/2026ApprovedFALSE
- 6.02.03.11.02.01.01The induction septum field alignment within the magnet, position and alignment values shall be within the following tolerance limits: (Note: Z is along the beam axis)10/12/2026ApprovedFALSE
- 6.02.03.11.02.01.01The induction septum field center displacement (measured with respect to the physical magnet center) shall be X=±150 (µm), Y=±150 (µm), Z=±150 (µm).10/12/2026ApprovedFALSE
- 6.02.03.11.02.01.01The induction septum field rotational alignment (measured with respect to the physical magnets primary axis X, Y, Z) shall be X=±0.1 (mrad), Y=±0.1 (mrad), Z=±0.2 (mrad).10/12/2026ApprovedFALSE
- 6.02.03.11.02.01.01The induction septum shall be designed to meet the following field quality/multipole requirements.10/12/2026ApprovedFALSE
- 6.02.03.11.02.01.01The harmonic reference radius at which the induction septum field quality shall be measured is 25(mm).10/12/2026ApprovedFALSE
- 6.02.03.11.02.01.01The field (Bref) or design energy or rigidity for which the induction septum field quality shall be measured are 52.03 (Tm) and 81.12 (Tm).10/12/2026ApprovedFALSE
- 6.02.03.11.02.01.01The induction septum shall have the following multipole content or dB/B within the specified measurement v olumes:10/12/2026ApprovedFALSE
- 6.02.03.11.02.01.01b1 = 10000, a1 ≤ ±1010/12/2026ApprovedFALSE
- 6.02.03.11.02.01.01b2 < ±10, a2 ≤ ±1010/12/2026ApprovedFALSE
- 6.02.03.11.02.01.01b3 < ±10, a3 ≤ ±1010/12/2026ApprovedFALSE
- 6.02.03.11.02.01.01b4 < ±10, a4 ≤ ±1010/12/2026ApprovedFALSE
- 6.02.03.11.02.01.01b5 < ±10, a5 ≤ ±1010/12/2026ApprovedFALSE
- 6.02.03.11.02.01.01b6 < ±10, a6 ≤ ±1010/12/2026ApprovedFALSE
- 6.02.03.11.02.01.01b7 < ±10, a7 ≤ ±1010/12/2026ApprovedFALSE
- 6.02.03.11.02.01.01b8 < ±10, a8 ≤ ±1010/12/2026ApprovedFALSE
- 6.02.03.11.02.01.01b9 < ±10, a9 ≤ ±1010/12/2026ApprovedFALSE
- 6.02.03.11.02.01.01b10 < ±10, a10 ≤ ±1010/12/2026ApprovedFALSE
- 6.02.03.11.02.01.01b11 < ±10, a11 ≤ ±1010/12/2026ApprovedFALSE
- 6.02.03.11.02.01.01b12 < ±10, a12 ≤ ±1010/12/2026ApprovedFALSE
- 6.02.03.11.02.01.01b13 < ±10, a13 ≤ ±1010/12/2026ApprovedFALSE
- 6.02.03.11.02.01.01b14 < ±10, a14 ≤ ±1010/12/2026ApprovedFALSE
- 6.02.03.11.02.01.01b15 < ±10, a15 ≤ ±1010/12/2026ApprovedFALSE
- 6.02.03.11.02.01.01The induction septum fringe field shall not exceed 10 Gauss on the path of the circulating beam in HSR.10/12/2026ApprovedFALSE
- 6.02.03.11.02.01.01The induction septum field shall have a field homogeneity of better than 2x10-3.10/12/2026ApprovedFALSE
- 6.02.03.11.02.01.01The magnet-cross-talk from the induction septum on the HSR circulating beam shall be less than 1x10-4, with respect to the main field on injected beam.10/12/2026ApprovedFALSE
- 6.02.03.11.02.01.01The induction septum shall be designed with components capable of withstanding a radiation dose of 1 (MGy).10/12/2026ApprovedFALSE
- 6.02.03.11.02.01.01The induction septum design and verification process shall ensure the final magnet will meet the reliability needs of the EIC over its planned operational life of >30 years.10/12/2026ApprovedFALSE
HIN-PPD-PS : HIN PPD Power Supplies
HIN-PPD-PS-DCSPTM : HIN PPD DC Septum Magnet Power Supply
- 6.02.03.11.01The magnet model being powered is the DC septum.10/12/2026ApprovedFALSE
- 6.02.03.11.01The DC septum power supply shall meet all requirements to deliver the magnet operational parameters defined in the Technical Magnet documentation. [Document#: EIC-SEG-RSI-196]10/12/2026ApprovedFALSE
- 6.02.03.11.03.02The DC septum power supply shall be a linear topology.10/12/2026ApprovedFALSE
- 6.02.03.11.03.02The voltage to ground of the DC septum being powered shall be 50 (V).10/12/2026ApprovedFALSE
- 6.02.03.11.03.02The DC septum power supply current type shall be DC.10/12/2026ApprovedFALSE
- 6.02.03.11.03.02The DC septum power supply waveshape di/dt (slew rate) shall be adjustable to limit overvoltage on the magnet.10/12/2026ApprovedFALSE
- 6.02.03.11.03.02The DC septum power supply AC Input voltage shall be 3 phase 480 (VAC).10/12/2026ApprovedFALSE
- 6.02.03.11.03.02The minimum current the DC septum power supply must operate at shall be 0 (A).10/12/2026ApprovedFALSE
- 6.02.03.11.03.02The maximum current the DC septum power supply must operate at shall be 5500 (A).10/12/2026ApprovedFALSE
- 6.02.03.11.03.02The flat top current stability of DC septum power supply shall be 100 (ppm) of 60 (%) of rated current.10/12/2026ApprovedFALSE
- 6.02.03.11.03.02The long term stability of the DC septum power supply shall be 100 (ppm) of full scale current.10/12/2026ApprovedFALSE
- 6.02.03.11.03.02DC septum power supply shall have a max current ripple of 550 (mA) between 0.1 (Hz) and 10 (kHz).10/12/2026ApprovedFALSE
- 6.02.03.11.03.02The DC septum power supply current setpoint scaling shall be 0-10 (V) = 0-5500 (A).10/12/2026ApprovedFALSE
HIN-PPD-PS-HSLK : HIN PPD Stripline Kicker Magnet Power Supply
- 6.02.03.11.01The magnet model being powered is stripline kicker.10/12/2026ApprovedFALSE
- 6.02.03.11.01The stripline kicker power supply shall meet all requirements to deliver the magnet operational parameters defined in the Technical Magnet documentation. [Document#: EIC-SEG-RSI-196]10/12/2026ApprovedFALSE
- 6.02.03.11.01The stripline kicker power supply chassis and outer conductor of the high voltage output cable shall be grounded.10/12/2026ApprovedFALSE
- 6.02.03.11.01The stripline kicker power supply shall provide a pulsed voltage.10/12/2026ApprovedFALSE
- 6.02.03.11.01The stripline kicker power supply maximum voltage shall be at least 30 (kV).10/12/2026ApprovedFALSE
- 6.02.03.11.01The stripline kicker power supply voltage rise time (2–98% of full-scale amplitude) shall be < 7 (ns).10/12/2026ApprovedFALSE
- 6.02.03.11.01The stripline kicker power supply voltage fall time (98–2% of full-scale amplitude) shall be < 25 (ns).10/12/2026ApprovedFALSE
- 6.02.03.11.01The stripline kicker power supply voltage flat top time shall be longer than 35 (ns).10/12/2026ApprovedFALSE
- 6.02.03.11.01The stripline kicker power supply voltage flat top repeatability shall be ±1 (%).10/12/2026ApprovedFALSE
- 6.02.03.11.01The stripline kicker power supply uniformity of the flattop shall be ±1 (%).10/12/2026ApprovedFALSE
- 6.02.03.11.01The stripline kicker power supply jitter of the rise time between the positive and negative voltage shall be < 1 (ns).10/12/2026ApprovedFALSE
- 6.02.03.11.01The stripline kicker power supply shall maintain a long-term stability of ±1 (%) of full scale voltage.10/12/2026ApprovedFALSE
- 6.02.03.11.01The stripline kicker power supply shall provide a minimal voltage setpoint resolution of 0.1 (kV).10/12/2026ApprovedFALSE
- 6.02.03.11.01The stripline kicker power supply rise time synchronization between power supplies (jitter) shall be <1 (ns).10/12/2026ApprovedFALSE
- 6.02.03.11.01The stripline kicker power supply burst mode shall support a repetition rate of 4 pulses separated by 100 (ms) repeated every AGS cycle.10/12/2026ApprovedFALSE
HIN-PPD-PS-INDSPTM : HIN PPD Induction Septum Magnet Power Supply
- 6.02.03.11.01The magnet model being powered is the induction septum.10/12/2026ApprovedFALSE
- 6.02.03.11.01The induction septum power supply shall meet all requirements to deliver the magnet operational parameters defined in the Technical Magnet documentation. [Document#: EIC-SEG-RSI-196]10/12/2026ApprovedFALSE
- 6.02.03.11.02.02The induction septum power supply shall be capable of powering a magnet with resistance of approximately 50 (mΩ).10/12/2026ApprovedFALSE
- 6.02.03.11.02.02The induction septum power supply shall be capable of powering a magnet with a maximum inductance of 666.341 (µH).10/12/2026ApprovedFALSE
- 6.02.03.11.02.02The voltage to ground of the induction septum being powered shall be TBD1 (V).10/12/2026ReviewedFALSE
- 6.02.03.11.02.02The induction septum power supply current waveform shall be a half sine wave.10/12/2026ApprovedFALSE
- 6.02.03.11.02.02The induction septum power supply’s peak waveshape di/dt during ramping shall be TBD1.10/12/2026ReviewedFALSE
- 6.02.03.11.02.02The induction septum power supply shall be capable of producing 1267 (A) peak.10/12/2026ApprovedFALSE
- 6.02.03.11.02.02The induction septum power supply peak current shall have a stability of 100 (ppm) of full scale current.10/12/2026ApprovedFALSE
- 6.02.03.11.02.02The time period for the induction septum power supply to reach specified stability shall be no more than 6 (s).10/12/2026ApprovedFALSE
- 6.02.03.11.02.02The induction septum power supply current setpoint resolution (min size in bits) shall be TBD1 bits.10/12/2026ReviewedFALSE
- 6.02.03.11.02.02The induction septum power supply shall be capable of producing up to 960 (V) for a 3.2 (ms) pulse.10/12/2026ApprovedFALSE
- 6.02.03.11.02.02The induction septum power supply shall have an interlock for the magnet thermal switch.10/12/2026ApprovedFALSE