Requirement Details
Electron Ion Collider
P-ESR-INST-BPM-ELEC.7
Requirement details, history, relationships and interfaces associated with requirement P-ESR-INST-BPM-ELEC.7
- CURRENT RECORD
- ARCHIVE RECORDS
- RELATIONSHIPS
- INTERFACES
Record Date: 11/13/2023 00:00 | |||
Identifier: | P-ESR-INST-BPM-ELEC.7 | WBS: | 6.04.06 |
Date Modified: | TBD: | FALSE | |
Status Date: | 08/01/2023 00:00 | Status: | APPROVED |
Description: | For newly injected refill bunches , with low charge (2nC bunches), in presence of stored beam, the measurement resolution shall be H=50 V=10 um |
||
Comments: |
No archive versions
Parents | |
No parents. | |
Children | |
No children. |